AC10 Inverter
F460 AI1channel input mode
Setting range:
0: straight line mode
1: folding line mode
Mfr’s value: 0
F461 AI2 channel input mode
Setting range:
0: straight line mode
1: folding line mode
Mfr’s value: 0
F462 AI1 insertion point A1 voltage value (V) Setting range: F400
~
F464 Mfr’s value: 2.00
F463 AI1 insertion point A1 setting value
Setting range: F401
~
F465 Mfr’s value: 1.20
F464 AI1 insertion point A2 voltage value (V) Setting range: F462
~
F466 Mfr’s value: 5.00
F465 AI1 insertion point A2 setting value
Setting range: F463
~
F467 Mfr’s value: 1.50
F466 AI1 insertion point A3 voltage value (V) Setting range: F464
~
F402 Mfr’s value: 8.00
F467 AI1 insertion point A3 setting value
Setting range: F465
~
F403 Mfr’s value: 1.80
F468 AI2 insertion point B1 voltage value (V) Setting range: F406
~
F470 Mfr’s value: 2.00
F469 AI2 insertion point B1 setting value
Setting range: F407
~
F471 Mfr’s value: 1.20
F470 AI2 insertion point B2 voltage value (V) Setting range: F468
~
F472 Mfr’s value: 5.00
F471 AI2 insertion point B2 setting value
Setting range: F469
~
F473 Mfr’s value: 1.50
F472 AI2 insertion point B3 voltage value (V) Setting range: F470
~
F412 Mfr’s value: 8.00
F473 AI2 insertion point B3 setting value
Setting range: F471
~
F413 Mfr’s value: 1.80
When analog channel input mode selects straight-line, please set it according to the
parameters from F400 to F429. When folding line mode is selected, three points A1(B1,
A2(B2), A3(B3) are inserted into the straight line, each of which can set the according
frequency to input voltage. Please refer to Figure 9-9:
Figure 9-9 Folding analog with setting value
F400 and F402 are lower/upper limit of analog AI1 input. When F460=1
,
F462=2.00V,
F463=1.4, F111=50, F203=1, F207=0, then A1 point corresponding frequency is (F463-1
)
*F111=20Hz, which means 2.00V corresponding to 20Hz. The other points can be set by the
same way.
AI2 channel has the same setting way as AI1.
9.5 Multi-stage Speed Control
The function of multi-stage speed control is equivalent to a built-in PLC in the inverter. This
function can set running time, running direction and running frequency.
AC10 series inverter can achieve 15-stage speed control and 8-stage speed auto circulating.
During the process of Flycatching, multi-stage speed control is invalid. After Flycatching is
finished, inverter will run to target frequency according to the setting value of parameters.
AI1
VOLTS
F465
F463
F403
Corresponding Frequency(Hz)
F402
F467
F460=1
AI1
F462
F464
F466
F461=1
AI2
Hz
F400
F401
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...