   English

3 / 14

  ATT140-340 

4 Commissioning

4.1 Preliminary checks

Before starting the dryer, make sure: 

•  installation was carried out according that given in the section 9.2;
•  the air inlet valves are closed and that there is no air fl ow through 
the dryer;
•  the power supply is correct.

4.2 Starting

Before starting the dryer follow the following instruction:

•  Switch the power on by turning the MAIN SWITCH (IG)  

&

  to “ 

ON”.
•  the crankcase heater will now start heating

!Y 

THE CRANKCASE HEATER MUST BE SWITCHED ON 12 

HOURS BEFORE STARTING THE DRYER.
Failure to comply with this rule may cause serious damage to the com-
pressor.

•  Shows the “MAIN SCREEN VIEW on display. 

Start the air compressor.
Start-up procedure dryer:

Press 
to enter on “Main Menu”

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Select

 START/STOP

and confi rm with 

Enter

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Select:

NORMAL START/STOP 

and confi rm with  

Enter

- On/Off Menu -

NORMAL START/STOP

STOP DIRECTLY

Confi rm 

START

, for the start-up

ENABLE UNIT RUNNING

STOP

“Compressed Inlet Air” pressure 
insuffi cient, dryer blocked.

INSUFFICIENT AIR PRESSURE

!Y

 Attention: The  air compressor must be started before the 

dryer. Otherwise you may damage the electric resistance.

The fi rst start-up is in “Forced Regeneration” on default. 
The unit works for a complete cycle (2 columns), after switches to normal 
working.

It is recommended to complete this type of starting with the air out-

let valve closed, to preserve the correct operation of the desiccant bed.

4.3 Operation

Leave the dryer in working during the period of working of the air com-
pressor.

•  The dryer works automatically, calibrations are not required on the 
fi eld;
•  if there are excessive and unexpected air fl ows, by-pass to avoid 
overloading the dryer.

4.4  Operation with Dew point control

In the case of work loads below the nominal or if you want different dew 
point of -40 ° C, it is possible to work in 

Dew Point Control

. The system 

automatically controls the time of the cycles of operation to obtain and 
maintain the predetermined dew point, with the result of energy saving in 
case of work with partial loads.
Procedure to set “dew point control”.

Press Prg  to enter on main menu 
Using 

Up

 and 

Down

 select

USER SETTINGS”

Press 

Enter

 to confi rm.

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Shows the “User settings menu

- User Settings Menu - 

DRYER SETTINGS

DATE/TIME

BMS

MOISTURE DRAIN

OTHER

LANGUAGE

Using 

Up

 and 

Down

 select

“DRYER SETTINGS”

Press 

Enter

 to confi rm.

- User Settings Menu - 

DRYER SETTINGS

DATE/TIME

BMS

MOISTURE DRAIN

OTHER

LANGUAGE

Using 

Up

 and 

Down

 select

the parameter.
Press 

Enter

 to confi rm..

U1 - DEWP.SET (°C):                       -40

U2 - PRESSURE (barg):                   07 

U3 - MODE: Forced Rig.
U4 - ALARM RELAY MODE:
by: ALARMS & WARNINGS

U6 -  DPM:                NO FITTED

Select the parameter 

U1- DEWP.SET

 (°C) and set the value you need. 

Press

 Enter 

to confi rm. see Table 1 for identifying the correct value 

to be set

Select the parameter 

U6- DPM

: set the mode 

FITTED.

 Press

 Enter 

to confi rm.

Table 1

Dew
Point

Application

-70°C

Request for a very low dew point.

-40°C

Request for a very low dew point.
(depend on the type of the process.).

-20°C

Request for a low dew point. 
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above -10 to -15 ° C.

-10°C

Request for a low dew point.
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above  -5°C.

0°C

Request for a dew point standard.
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above  10°C.

Important: for correct readings, the Dew point sensor must work at 
a precise air fl ow, which is adjusted by a fl ow meter (no. 33).
CORRECT CALIBRATION: LEVEL    2 ÷ 5     liters/minutes
To ensure optimal Dew point  sensor operation, comply with the 
maintenance instructions given in para. 6.4. 
In this regard, the sensor connection is fi tted with a shut-off valve to 
facilitate maintenance

Содержание ATT140

Страница 1: ...IT Manuale d uso EN User Manual ES Manual de uso DE Benutzer Handbuch ATT140 ATT260 ATT340 DATE 04 05 2017 Rev 21 CODE 398H272986 ATT Antares Tandem Dryer 50Hz...

Страница 2: ......

Страница 3: ...comunque in modo che non venga generata alcuna situazione di rischio I rischi che non stato possibile eliminare in fase di progettazione sono riportati nella tabella seguente Parte Considerata Rischi...

Страница 4: ...dell ambiente circostante conten ga contaminanti solidi e o gassosi attenzione quindi a zolfo ammonia ca cloro e ad installazioni in ambiente marino Per le versioni con ventilatori assiali sconsigliat...

Страница 5: ...verso da 40 C possibile lavorare in modalit Dew Point Control Il sistema automaticamente controller la durata dei cicli di funzionamento per raggiungere e mantenere il dew point desiderato risparmiand...

Страница 6: ...VICE INFORMATION Selezionare Language e confermare con Enter User Settings Menu DRYER SETTINGS DATE TIME BMS MOISTURE DRAIN OTHER LANGUAGE Selezionare con UP e DOWN la lingua Confermare con Enter LANG...

Страница 7: ...matico manuale Una volta modificato il parametro confermare con Enter Le altre maschere visualizzabili in questa sezione sono le seguenti Premere Esc per tornare a USER SETTINGS MENU Selezionare DATE...

Страница 8: ...SAVING 000000009 Questa maschera accessibile dalla maschera principale premendo due volte il tasto DOWN dalla maschera principale Procedura per l abilitazione di tale maschera 1 Accedere in PRG USER...

Страница 9: ...a Y L apparecchiatura contiene gas fluorurati a effetto serra Il fluido frigorigeno R407c a temperatura e pressione normale un gas incolore appartenente al SAFETY GROUP A1 EN378 fluido gruppo 2 second...

Страница 10: ...ngresso aria n 22 Attenzione il dryer ancora in pressione nella zona di uscita aria cooler 3 depressurizzare l impianto utilizzando una valvola in uscita se presente o utilizzare lo scarico del filtro...

Страница 11: ...re NU X A 3 s AIN sonda sullo scarico compressore non funzionate S N Attivo A07 WARNING PROBE Thermal MassTemperature NU X A 3 s AIN sonda temperatura massa termica non funionante N N Attivo A08 WARNI...

Страница 12: ...alta pressione pressostato A N N Attivo A22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN bassa pressione pressostato B N N Attivo A23 WARNING ADSORBER High Pressure Column 2 X X X A 120s D...

Страница 13: ...X A Errore sonda di pressione colonna 1 N N Attivo A37 WARNING PROBE PRESSU RE COLUMN 2 NU X X A Errore sonda di pressione colonna 2 N N Attivo A38 WARNING Pressure Discharge Failure Column 1 NU X X A...

Страница 14: ...sore No Si Mancanza di refri gerante Si Pulire il condensatore Elevata perdita di carico Scambiatore intasato No Filtri intasati No Formazione ghiaccio No Si Pulire lo scambiatore e sostituire prefilt...

Страница 15: ...ntilatore starato No Mancanza refrigerante ricaricare Z Si Sostituire pressosta to ventilatore Z No Carico termico eccessivo No Low AD inlet temperature Valvola gas caldo starata Si No Pressostato ven...

Страница 16: ...Italiano 14 14 ATT140 340...

Страница 17: ...med in accordance with the information and instructions given in the technical documentation supplied and always in such a way to avoid the creation of a hazardous situation The risks that it has not...

Страница 18: ...void installations where the surrounding air contains solid and or gaseous pollutants e g sulphur ammonia chlorine and installations in marine environments The ducting of extracted air is not recommen...

Страница 19: ...ifferent dew point of 40 C it is possible to work in Dew Point Control The system automatically controls the time of the cycles of operation to obtain and maintain the predetermined dew point with the...

Страница 20: ...TTINGS SERVICE INFORMATION Select Language Press Enter to confirm User Settings Menu DRYER SETTINGS DATE TIME BMS MOISTURE DRAIN OTHER LANGUAGE Using UP and DOWN select the language Press Enter to con...

Страница 21: ...point mode automatic manual When you change the parameter press Enter to confirm Press Esc to return on USER SETTINGS MENU Select DATE for change the date and the time User Settings Menu DRYER SETTIN...

Страница 22: ...This Screen appears ENERGY SAVING 000000009 Steps to enable these functions 1 Press PRG than USER than SETTINGS than OTHER This Screen appears U12 BACKLIGHT ON NO U13 Enable Money NO U14 Money Euro U...

Страница 23: ...any damage caused by incorrect refrigerant replacement carried out by unauthorized personnel will not be covered by the war ranty Y The equipment contains fluorinated greenhouse gases At normal temper...

Страница 24: ...urize the dryer using a valve air out cooler if installed by the user or use the drain valve of the dust filter 29 4 Make sure that the pressure on gauge 0 bar AIR OUT n 36 37 The desiccant vessels ar...

Страница 25: ...A 3 s AIN Compressor Discharge Temperature Y N Active A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN Thermal Mass Temperature PROBE Not Connected Or Faulty N N Active A08 WARNING PROBE Capa...

Страница 26: ...22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN Air Pressure Switch B N N Active A23 WARNING ADSORBER High Pressure Column 2 X X X A 120s DIN Air Pressure Switch B N N Active A24 WARNING AD...

Страница 27: ...X A Error pressure PROBE column 1 N N Active A37 WARNING PROBE PRES SURE COLUMN 2 NU X X A Error pressure PROBE column 2 N N Active A38 WARNING Pressure Dis charge Failure Column 1 NU X X A If at the...

Страница 28: ...eteriorated No Yes low level refrigerant Yes Clean the condenser High pressure drop Exchanger dirty No Filters dirty No Formazione ghiaccio No Yes Clean the exchenger and substitute the pre filter Yes...

Страница 29: ...switch PV not set No refrigerant recharge Z Yes Replace pressure switch Z Excessive thermal load Low AD inlet Tem peratur Hot gas valve not cali brated Yes Fan pressure switch PV not set Calibrate va...

Страница 30: ...English 14 14 ATT140 340...

Страница 31: ...ndo la generaci n de situaciones peligrosas En la siguiente tabla se recogen los riesgos que no se hayan podido eliminar en la fase de dise o Pieza afec tada Riesgo residual Forma de exposi ci n Preca...

Страница 32: ...cloro e instalaciones en entornos marinos La ventilaci n del aire extra do no es recomendada para las versiones con ventiladores axiales 3 5 Conexi n el ctrica Use un cable aprobado de acuerdo con la...

Страница 33: ...Punto de Roc o El sistema controla de forma autom tica la duraci n de los ciclos de funcionamiento para obtener y mantener el punto de roc o predeter minado ahorrando energ a en caso de trabajar con...

Страница 34: ...ndo la m quina est apagada 4 6 Selecci n de idioma Seleccione USER SETTINGS Pulse Enter para confirmar Main Menu START STOP USER SETTINGS SERVICE INFORMATION Seleccione Language Pulse Enter para confi...

Страница 35: ...las Up Down y Enter puede seleccionar cambiar un par metro U1 SET de Punto de Roc o U2 presi n de trabajo barg U3 Modo de Trabajo Forced Rig O Normal U4 Modo de Aviso de Alarma mediante alarmas y adve...

Страница 36: ...OFF OPEN L SWITCH Closed CLOSE L SWITCH Open 5 4 Ahorro de energ a 5 4 1 AHORRO DE ENERG A kWh El usuario puede ver c mo la unidad ahorra kWh en comparaci n con un aparato similar de los siguientes ti...

Страница 37: ...ga de refrigerante p ngase en contacto con personal cualificado y autorizado Y La v lvula Schrader s lo deber utilizarse en caso de que el apa rato no funcione de lo contrario cualquier da o causado p...

Страница 38: ...marquen 0 bar entrada del aire n 22 Atenci n el secador todav a est bajo presi n en la zona de salida del aire del enfriador 3 Despresurizar el sistema utilizando una v lvula en salida si est present...

Страница 39: ...Temperature Nu X A 3 s AIN Temperatura de descarga del compresor S N Activo A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN PROBE de la Temperatura de Masa t rmica No Co nectado o Defectuoso...

Страница 40: ...N Interruptor de Presi n del Aire A N N Activo A22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN Interruptor de Presi n del Aire B N N Activo A23 WARNING ADSORBER High Pressure Column 2 X X...

Страница 41: ...vo A37 WARNING PROBE PRESSU RE COLUMN 2 NU X X A Error PROBE de presi n columna 2 N N Activo A38 WARNING Pressure Dischar ge Failure Column 1 NU X X A Si al final de la fase de drenaje la presi n es 3...

Страница 42: ...l com presor deteriorados No S Nivel bajo refrigerante S Limpie el conden sador Ca da de la alta presi n Intercambiador sucio No Filtros sucios No Formaci n de hielo No S Limpie el inter cambiador y c...

Страница 43: ...rigerante recarga Z S Cambie el interruptor de la presi n Z Carga t rmica excesiva Temperatura de entrada AD baja V lvula de gas caliente sin calibrar S Interruptor de presi n del ventilador PV sin co...

Страница 44: ...Espa ol 14 14 ATT140 340...

Страница 45: ...in den technischen Ger teunterlagen strikt einzuhalten in jedem Fall ist jedes Vorgehen zu vermeiden dass zu ei ner Gefahrensituation f hrt Die Restrisiken die beim Bau der Maschine nicht beseitigt w...

Страница 46: ...rs sollte von einer Installation in Bereichenabgesehenwerden indenendieLuftfesteund odergasf rmige kontaminierende Stoffe enth lt z B Schwefel Ammoniak Chlor das gilt auch f r Installationen in Meeres...

Страница 47: ...verschiedener Taupunkt gew nscht wird kann die Betriebsart Taupunktregelung gew hlt werden Das System berwacht automatisch die Dauer der Arbeitszyklen um den gew nschten Tau punkt zu erreichen oder a...

Страница 48: ...status OFF Keine Luft in die Tanks mit dem Trock nungsmittel einstr men lassen wenn die Maschine ausgeschaltet ist 4 6 Sprache anw hlen USER SETTINGS anw hlen und mit Enter best tigen Main Menu START...

Страница 49: ...r zu ndernde Parameter ausgew hlt U1 EINSTELLWERT Taupunkt U2 Arbeitsdruck barg U3 Betriebsart Zwangreg O Normal U4 Alarm Relay Mode by alarms warnings oder nur Fehlermeldungen U6 DPM Fitted oder No F...

Страница 50: ...ige der Energieersparnis 5 4 1 ANZEIGE DER ENERGIEEINSPARUNG IN kWh Es ist m glich die Energieeinsparung der Maschine in kWh im Vergleich zu einem der folgenden analogen Ger te anzuzeigen Kalt regener...

Страница 51: ...Das Schrader Ventil darf nur im Falle einer ungew hnlichen Be triebsst rung verwendet werden anderenfalls bestehen bei einer fal schen K ltemittelbef llung keine Garantieanspr che 6 2 K ltemittel Y B...

Страница 52: ...ass Nr 22 ob der Druck 0 bar betr gt Achtung Der Trockner steht im Luftauslassbereich des K hlers noch unter Druck 3 Setzen Sie das System mit Hilfe des Luftauslassventils sofern vorhanden oder des Ab...

Страница 53: ...sor DischargeTemperature Nu X A 3 s AIN F hler am Kompressorauslass defekt J N Aktiv A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN Temperaturf hler thermische Masse defekt N N Aktiv A08 WAR...

Страница 54: ...DIN Hochdruck Druckschalter A N N Aktiv A22 WARNING ADSORBER Low Pres sure Column 2 X X X A 120s DIN Niederdruck Druckschalter B N N Aktiv A23 WARNING ADSORBER High Pres sure Column 2 X X X A 120s DIN...

Страница 55: ...6 WARNING PROBE PRESSU RE COLUMN 1 NU X X A Fehler Druckf hler S ule 1 N N Aktiv A37 WARNING PROBE PRESSU RE COLUMN 2 NU X X A Fehler Druckf hler S ule 2 N N Aktiv A38 WARNING Pressure Dischar ge Fail...

Страница 56: ...digt Nein Ja K ltemittel unzureichend Ja Den Kondensator rei nigen Hohe Druckverluste W rmetauscher verstopft Nein Filter verstopft Nein Eisbildung Nein Ja W rmetauscher reinigen und Vorfilter ersetz...

Страница 57: ...f llen Z Ja Druckw chter ersetzen Z W rmelast zu hoch Niedriger AD Eintritt temperatur Hei gas Ventil unkorrekt eingestellt Ja Druckw chter Ven tilator PV unkorrekt eingestellt Ventil einstellen Z Nie...

Страница 58: ...Deutsch 14 14 ATT140 340...

Страница 59: ......

Страница 60: ...co MI Italy Sede Operativa Gas Separation and Filtration Division EMEA Strada Zona Industriale 4 35020 S Angelo di Piove PD Italy tel 39 049 971 2111 fax 39 049 9701911 Web site www parker com hzd e m...

Отзывы: