Ø110 x 495 (max. working pressure 480 bar)
Replacement of active carbon
– molecular sieve cartridge
1. Unscrew the filter head counter clockwise by placing the special tool on top of the two Allen bolts.
Then use the appropriate tool to take out the filter head.
2. Remove the filter head and the spring.
3. Place the
special handle
on top of the A.C.-M.S cartridge.
4. Remove the A.C.-M.S. cartridge by pulling upwards with the
special handle.
Before throwing
away the used cartridge, do not forget to remove from them the cartridge connector.
5. Clean the inside of the filter housing with a clean cloth.
6. Remove the new A.C.-M.S. cartridge from their protective case. Be sure that packaging is not
punctured. If it is damaged do not use it.
7. Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
8. Replace the o-ring of the cartridge connector, lay a small amount of silicone grease on the new o-
ring and then screw the connector on the new A.C.-M.S. cartridge.
9. Place the new A.C.-M.S. cartridge in the filter housing and fasten it down by hand on the
coalescing connector (see also drawing nr. B).
10. Lay a small amount of silicone grease on the o-rings of the filter head. If there is a trace of
damage on the o-rings, replace.
11. Install the spring in between the filter head and the cartridge.
12. Screw the filter head carefully using the appropriate tool with light pressure until it fits evenly to the
filter housing.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.
FILTER HEAD & FILTER HOUSING SHOULD BE ADJOINED ON TOP WHEN REINSTALLING.