User Manual -
Typhoon Open –
12/2013 edition
.
PARAMINA SA
– Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
- website:
www.paramina-compressors.com
26
General Service Instructions
CAUTION: Before any maintenance work on the compressor, make sure there is
not air inside, under pressure.
Maintenance work must always be done with the compressor stopped and
disconnected from the mains supply.
Operating hours
Every
20 hrs
30 hrs
50 hrs
Every
100 hrs
Every
200 hrs
Every
500 hrs
Every
1000 hrs
Every
6 mths
Every
12 mths
Check
V - Belt tension
1
st
X
Check oil level *
Daily
Change of oil **
1
st
X
X
Replace the
air intake cartridge***
X
X
Replace
the BA
cartridge
– Filter
Ø80 x 535
**
Open 15
X****
X
Open 18
N/A
X
Replace
the BA
cartridge
– Filter
Ø110 x
495 **
Open 15
35 hrs****
X
Open 18
28 hrs****
X
Replace the
coalescing
cartridge ***
X
X
Check Valves
X
Replace Valves
X
Replace pistons
and piston rings
X
Replace filling hoses
Every 2000 hrs or once per 5 years
ATTENTION
* Check every day the oil level and the general condition of the compressor. Check all connections for
leakage.
**
After 6 months, you have to replace the oil and the
BA filter’s cartridge(s), whether they have completed
the required operating hours or not. If the compressor is out of operation for a long period of time, you
must also replace them before restart.
The proper quantity of oil, when you replace it, is
2,2 lit.
Never mix different types of oil.
The compressor unit is delivered filled with
PARAMINA HP OIL
(Synthetic oil).
***
After 12 months, you have to replace the coalescing cartridge and the air intake cartridge whether they
have completed the required operating hours or not.
**** measured @ 20
o