SECTION TWO Operation (user instructions)
ELECTRICAL CONNECTION
(WARNING: THIS APPLIANCE MUST BE EARTHED)
This appliance is suitable for use on 220 - 240V 50Hz mains
supply only.
The wiring in the mains lead on this appliance
is colour
coded as follows:-
Green & Yellow -
Earth
Blue
-
Neutral
Brown
-
Live
The mains plug terminal should be connected as shown and a 3A fuse must be used to protect the appliance.
The appliance control knob and fan switches are located behind the fret on the left hand side.
The full lighting procedure is as follows: -
OPERATING THE FAN
A.
Ensure that the electricity supply is connected and switched on.
B.
Lift off the ash pan cover and press the switch marked on. The red light at the base of the control unit will
illuminate and the fan should operate at the high speed. After a short period (up to 20 seconds) the light will
extinguish, the fan speed will reduce and the fire can be lit (see Lighting the Fire).
C.
If the red light does not illuminate on initial operation, or the fan does not run press the switch
marked OFF to reset the control and wait approximately 1 min. before repeating steps 'a' and 'b'
above.
D.
During normal use the red light may illuminate indicating a flue restriction (this may be due to a
flue obstruction or adverse wind conditions). In these circumstances the fan speed will increase and
if the condition is not corrected in approximately 10 seconds the gas supply will be shut off. The
control knob must be turned to the position and the off switch must be pressed to reset the
control. Before attempting to relight the fire wait 3 minutes. If this occurs refer to Section 3
“Cleaning Fan Outlet.”