SECTION EIGHT Siting the Appliance (installation instructions)
FLUE TERMINAL POSITION
The flue outlet must terminate on an outside wall.
The minimum flue terminal clearances, which must be maintained, are shown in fig.1: -
A.
Directly below an operable window or other opening, eg. air brick
300mm
B.
Below gutters, soil pipes or drain pipes
75mm
C.
Below eaves
200mm
D.
Below balconies or car port roof
200mm
E.
From vertical drain pipes and soil pipes
75mm
F.
From internal and external corners
150mm
G.
Above ground, roof or balcony level
150mm
H.
From a surface facing a terminal
600mm
I.
From a terminal facing a terminal
1200mm
J.
From an opening in the car port into the dwelling, e.g. door, window, etc.
1200mm
K.
Vertically from a terminal on the same wall
1500mm
L.
Horizontally from a terminal on the same wall
300mm