Introduction
The PARAGON FOCUS RS PLUS is an inset room sealed live fuel-effect gas appliance designed
for use in locations that do not have a conventional chimney. The appliance must be installed
against an outside wall because the air to support combustion is taken from the outside and the
products of combustion are expelled to the outside.
The appliance incorporates a safety device in the form of a FLAME SUPERVISION DEVICE,
which constantly monitors the flame and will cause the gas to be switched off if the flames are
extinguished for any reason.
THIS DEVICE MUST NOT BE OVERRIDDEN.
If this situation
occurs on a regular basis have the appliance checked by a qualified engineer. The problem may
be due to a blocked or restricted flue.
Before removing the fret, trim, glass or fuel bed for cleaning the fire should be turned off, and left
to cool down.
NOTE:
In use some discoloration of the components will take place in the combustion box, this is
normal, but can be kept to a minimum if the coals are placed correctly (i.e. after cleaning). See
Section 4.
As with all heating appliances certain areas (Working Surfaces) become very hot when the
appliance is in use. Only the ashpan knob and the gas control knob should be touched when the
fire is being used.
SECTION THREE
Operation
Do not use this appliance without the glass panel fitted, or if this panel is cracked or broken.
WARNING: If the burner or pilot is extinguished for any reason, do not attempt to
re-light the pilot for at least three minutes.
LIGHTING THE FIRE
The pilot can be left on or the pilot can be extinguished and relit each time the fire is used.
The appliance Control Knob is positioned behind the fret or fascia panel.
The full lighting procedure for MANUAL VERSION is as follows: -
a.
Push knob in as far as possible on gas control.
b.
Turn knob anti-clockwise until a click is heard. The knob will stop at the position marked
'
'
and a spark should be seen at the tip of the ignition probe. At the same time the pilot flame
should light. KEEP THE KNOB PRESSED IN FOR 20 SECONDS. Should the pilot fail to light,
turn the control knob clockwise to the
'
'
position, wait 3 minutes, and repeat the procedure.
c.
After lighting the pilot flame the control knob should be allowed to spring out slightly. This will
allow you to turn the knob further anti-clockwise to the position marked
'
'
. The pilot flame
should then ignite the main fire.
d.
It is possible to adjust the height of the flames by turning the control knob between the
positions marked
'
'
and
'
'
. Note that the knob 'latches' in position at either end of this
movement and must be pushed in slightly before it can be turned.
e.
To turn the fire off, depress the knob slightly and turn it to the
'
'
position.
f.
To completely extinguish the fire, depress the knob slightly and turn to
'
'
the position.