![Paragon Fires focus rs plus remote Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/paragon-fires/focus-rs-plus-remote/focus-rs-plus-remote_owners-manual_754384010.webp)
LT5944 Iss 1 (25/10/11)
10
PARAGON FOCUS RS PLUS
Installation Instructions
SECTION SIX
Appliance Data
Wall Cut-out dimensions:
Height
553mm
Width
405mm
Overall dimensions:
Height
601mm
Width
501mm
Forward Projection:
90mm, (From fireplace opening
Including typical fret.)
Weight:
38.5kg (Boxed excluding fret)
37kg (Unboxed excluding fret)
Flue Length and duct length:
100mm (minimum) to l metre (maximum)
Standard length supplied with fire-535mm (267mm
after cutting).
Additional 535mm & 1m tubes supplied as optional
extras. (No bends should be fitted in the flue pipe)
Pressure Test Point Location:
Gas inlet elbow
Gas Connection:
8.0mm O/D, tube.
Data Badge Location:
On the appliance base behind decorative fret.
Note: When flue length exceeds 200mm you may experience outing from cold. In this case it may be
necessary to remove the restrictor plate. Please ensure that the flue pipe has been adequately
sealed before undertaking removal of this plate.
MODEL
Propane Gas (G31) Version
Category of appliance
C
II
NO
X
Class
3
Efficiency Class
1
Gas Category
I
3P
Gas Type
G31 Propane Gas
Gas Pr/- 1.0mbar
37 mbar
Gas Input (Max)
4.9kW Gross
(Min)
2.4kW
Injectors size
116
NOTE: The efficiency of this appliance has been measured as specified in BS EN613-2001 and the
result is 79.25.% L.P.G. gas The gross calorific value of the fuel has been used for this efficiency
calculation. GasTec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating