Messages and Troubleshooting
6-3
7986-A2-GB20-00
September 1998
Device Messages
The Device Messages in Table 6-1, listed in alphabetical order, can appear in the
messages area at the bottom of the ATI screens.
Table 6-1.
Device Messages (1 of 2)
Device Message
What Message Indicates
What To Do
Access level is
Operator.
Configuration is
read-only.
The operator requested that
configuration options be
loaded, but does not have
authority to edit them.
If configuration options are to be
edited, use a Login ID that has
Administrator authority.
Cannot Save – no
Login IDs with Access
Administrator
All of the login IDs being
saved have an access level
below Administrator.
Change the access level of at
least one Login ID to
Administrator so that
configuration changes can be
made. (Operator-level users
cannot make configuration
changes.) Save the Login IDs.
Command Complete
Action requested has
successfully completed.
No action needed.
Invalid Character (
x )
A nonprintable ASCII
character (
x) has been
entered.
Reenter information using valid
characters.
Invalid – Data
Terminal Initiated
Loopback Active
Network-initiated loopback
was in progress when
another selection was
made.
No action needed.
Invalid Password
Login is required and an
incorrect password was
entered; access is denied.
H
Try again.
H
Contact your system
administrator to verify your
password.
Invalid – Send Pattern
Already Active
A pattern test was already
in progress when the Start
field was selected.
H
Allow test to continue.
H
Select another test.
H
Stop the test.
Invalid – [ Test ]
Already Active
The described test was
already in progress when
another selection was
made.
H
Allow test to continue.
H
Select another test.
H
Stop the test.
Invalid Test
Combination
A loopback or pattern test
was in progress when Start
was selected to start
another test, or was active
on the same or another
interface when Start was
selected.
H
Wait until other test ends and
message clears.
H
Abort all tests from the Test
menu screen.
H
Stop the test from the same
screen the test was started
from.
Содержание M/HDSL Standalone Termination Unit HOTWIRE...
Страница 44: ...Initial Startup and Configuration 3 18 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Страница 68: ...Testing 5 10 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Страница 80: ...Security 7 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Страница 106: ...Standards Compliance for SNMP Traps B 6 7986 A2 GB20 00 September 1998...
Страница 112: ...Cables and Pin Assignments C 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Страница 114: ...Technical Specifications D 2 7986 A2 GB20 00 September 1998 This page intentionally left blank...