4. Troubleshooting
4-2
June
2004
8620-A2-GN20-50
System Alarm
LED is ON (on a
line card)
SYSTEM ALM LED is ON
and line card is inoperative
in Slot
n
.
For an SCP-card-based chassis:
1. Using the Status - Alarms screen of
the web interface, determine what
alarms have been reported against
the line card.
2. If a major alarm is indicated, check
the Ethernet connections for the
SCP and line card.
3. Remove and reinstall the card.
4.
I
f unable to clear by reinstalling the
card, replace the card.
For an MCP-based chassis:
1. Choose Card Selection from the
Main Menu to display the status of
each line card.
2. If a major alarm is indicated, reset
the MCP card (
A-A-F
). Then, reset
the line card (
A-A-E
).
3. Remove and reinstall the card.
4.
I
f unable to clear by resetting the
card, replace the card.
Table 4-1.
Troubleshooting Table (2 of 2)
Symptom
Possible Cause
Solutions