Maintenance and Troubleshooting
5-8
9621-A2-GB20-30
August 1997
Message
What To Do
What It Indicates
The Frame Relay DLCI
Number [
DLCI number ]
is down on the [
DDS
Network/ Port-1/ Port-2/
BRI-B1 ] Interface.
Alarm has been
generated because the
specified Data Link
Connection Identifier is
down for the Network,
Port 1, Port 2, or ISDN
BRI DBM (BKP)
interface.
If Network interface:
Contact network provider.
If a port interface:
Verify that all connections to
frame relay equipment are
secure and operational on the
access unit identified.
If BRI-B1 interface:
Verify that the RJ45 backup
cable (ISDN-U) is properly
seated in the physical
interface (BKP).
Wait and see if the DLCI’s link
is active on the primary
destination link.
– If it is, no action is required.
– If not, contact network
provider.
No action is needed if
communicating directly with
another access unit. The other
unit has chosen to revert back
to the primary destination link.
Alarm Cleared. The
Frame Relay DLCI
Number [
DLCI number ]
is up on the [
DDS
Network/ Port-1/ Port-2/
BRI-B1 ] Interface.
Alarm condition no
longer exists.
—