COMSPHERE 3600 Series Data Service Units
4-44
July 1999
3610-A2-GB41-70
When full backup is in effect, there is no longer any
data communication from the DDS line. All tributaries are
communicating with the controlling DTE via the digital
bridge capability.
In a central-site multipoint dial backup configuration,
full backup is required if the DBM speed does not equal
the DSU speed, or if the control DSU reports No Signal or
Bipolar Violations. Under this condition, the bridge is
inactive during normal operation. To go into full backup,
the bridge may be activated by an 6800 Series NMS
Standby Facility (sf) command, or from the DCP Backup
(Bkup) command. Figures 4-36 and
4-37
illustrate this.
The 6700 Series NMS software uses a Device
Management window to indicate device status.
For full backup, it is assumed that the control DSU is
no longer receiving valid DDS timing. In this case, the
control DSU must be commanded from the DCP or NMS
to go into full backup. This action switches the connection
from the DDS line to the bridge and causes the digital
bridge to switch to the timing that is stored in the Brdg
Timing configuration option.
Figure 4-36. Central-Site Bridging Architecture (56 kbps) – Inactive Digital Bridge
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB41 70 Notices...
Страница 22: ...COMSPHERE 3600 Series Data Service Units 1 10 July 1999 3610 A2 GB41 70...
Страница 47: ...Model 3611 Installation 3 9 3610 A2 GB41 70 July 1999 Figure 3 3 Non Modular TDM or MCMP Installation...
Страница 52: ...COMSPHERE 3600 Series Data Service Units 3 14 July 1999 3610 A2 GB41 70...
Страница 64: ...COMSPHERE 3600 Series Data Service Units 4 12 July 1999 3610 A2 GB41 70 Figure 4 8 Digital Sharing...
Страница 67: ...Principles of Operation 4 15 3610 A2 GB41 70 July 1999 Figure 4 10 FEP Port Sharing...
Страница 91: ...Principles of Operation 4 39 3610 A2 GB41 70 July 1999 Figure 4 31 Multipoint DDS Circuit in Partial Backup...
Страница 93: ...Principles of Operation 4 41 3610 A2 GB41 70 July 1999 Figure 4 33 Tributary Addressing via Backup Connections...
Страница 102: ...COMSPHERE 3600 Series Data Service Units 4 50 July 1999 3610 A2 GB41 70 Figure 4 38 Bridged LADS Operation...
Страница 111: ...Principles of Operation 4 59 3610 A2 GB41 70 July 1999 Figure 4 47 Digital Sharing in a Multipoint Circuit...
Страница 113: ...Principles of Operation 4 61 3610 A2 GB41 70 July 1999 Figure 4 49 Digital Sharing in an MCMP Circuit LPDA 2 Monitoring...
Страница 114: ...COMSPHERE 3600 Series Data Service Units 4 62 July 1999 3610 A2 GB41 70...
Страница 140: ...COMSPHERE 3600 Series Data Service Units 5 26 July 1999 3610 A2 GB41 70 Figure 5 10 Digital Test...
Страница 149: ...DSU Operations 5 35 3610 A2 GB41 70 July 1999 Figure 5 13 Choosing Mode of Operation and Setting Configuration Options...
Страница 161: ...A 1 3610 A2 GB41 70 July 1999 Data Service Unit Menu A...
Страница 162: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB41 70...
Страница 163: ...Data Service Unit Menu A 3 3610 A2 GB41 70 July 1999...
Страница 164: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB41 70...
Страница 166: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB41 70 This page intentionally left blank...
Страница 170: ......
Страница 174: ......
Страница 196: ...COMSPHERE 3600 Series Data Service Units C 18 July 1999 3610 A2 GB41 70...
Страница 230: ...COMSPHERE 3600 Series Data Service Units D 34 July 1999 3610 A2 GB41 70...