COMSPHERE 3600 Series Data Service Units
4-34
July 1999
3610-A2-GB41-70
•
Case 5 – Aggregate switched backup for MCMP
circuits. An MCMP circuit can be backed up using
the aggregate switch capability of the DSU. In
Figure 4-27, the control DSU should be configured
so that AggrSwitch (Aggregate Switch) is enabled
and AgSw Timing (Aggregate Switch Timing) is
set to the appropriate timing source to be used
during dial backup. The Bridge is configured so
Brdg Timing (Bridge Timing) is set to Ext for
Port 1. The DBM-Ss are configured so that
TxClkSource (Transmit Clock Source) is set to
DDS. In addition, the DBM-S connected to the
aggregate switch port must have Diag Type
(Diagnostic Type) set to None or Disr.
To establish a partial backup, command the control
DBMs to call the remote DBMs using the Dial command,
followed by the sf command from the 6800 Series NMS
or
→
Dial command from the DCP. DSU timing is taken
from the DDS network.
To establish a full backup, send an sf command from
the 6800 Series NMS or
→
Dial command from the DCP
to the control DSU. The DSU disconnects from the DDS
line and derives its timing from the source specified in the
AgSw Timing configuration option.
The 6700 Series NMS provides two choices from the
Dial Standby status: Return to Lease or Return to Dial.
NOTE
During full backup switching (for
aggregate versions only),
commands are routed over the
aggregate port to the remote
DSU or DBM. Only two tests are
available to test the DDS facility,
Digital Test (DT) and Bit Error
Rate Test (BERT).
Figure 4-27. Aggregate Switched Backup for MCMP Circuit Configuration
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB41 70 Notices...
Страница 22: ...COMSPHERE 3600 Series Data Service Units 1 10 July 1999 3610 A2 GB41 70...
Страница 47: ...Model 3611 Installation 3 9 3610 A2 GB41 70 July 1999 Figure 3 3 Non Modular TDM or MCMP Installation...
Страница 52: ...COMSPHERE 3600 Series Data Service Units 3 14 July 1999 3610 A2 GB41 70...
Страница 64: ...COMSPHERE 3600 Series Data Service Units 4 12 July 1999 3610 A2 GB41 70 Figure 4 8 Digital Sharing...
Страница 67: ...Principles of Operation 4 15 3610 A2 GB41 70 July 1999 Figure 4 10 FEP Port Sharing...
Страница 91: ...Principles of Operation 4 39 3610 A2 GB41 70 July 1999 Figure 4 31 Multipoint DDS Circuit in Partial Backup...
Страница 93: ...Principles of Operation 4 41 3610 A2 GB41 70 July 1999 Figure 4 33 Tributary Addressing via Backup Connections...
Страница 102: ...COMSPHERE 3600 Series Data Service Units 4 50 July 1999 3610 A2 GB41 70 Figure 4 38 Bridged LADS Operation...
Страница 111: ...Principles of Operation 4 59 3610 A2 GB41 70 July 1999 Figure 4 47 Digital Sharing in a Multipoint Circuit...
Страница 113: ...Principles of Operation 4 61 3610 A2 GB41 70 July 1999 Figure 4 49 Digital Sharing in an MCMP Circuit LPDA 2 Monitoring...
Страница 114: ...COMSPHERE 3600 Series Data Service Units 4 62 July 1999 3610 A2 GB41 70...
Страница 140: ...COMSPHERE 3600 Series Data Service Units 5 26 July 1999 3610 A2 GB41 70 Figure 5 10 Digital Test...
Страница 149: ...DSU Operations 5 35 3610 A2 GB41 70 July 1999 Figure 5 13 Choosing Mode of Operation and Setting Configuration Options...
Страница 161: ...A 1 3610 A2 GB41 70 July 1999 Data Service Unit Menu A...
Страница 162: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB41 70...
Страница 163: ...Data Service Unit Menu A 3 3610 A2 GB41 70 July 1999...
Страница 164: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB41 70...
Страница 166: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB41 70 This page intentionally left blank...
Страница 170: ......
Страница 174: ......
Страница 196: ...COMSPHERE 3600 Series Data Service Units C 18 July 1999 3610 A2 GB41 70...
Страница 230: ...COMSPHERE 3600 Series Data Service Units D 34 July 1999 3610 A2 GB41 70...