Configuration Worksheet for MCMP Mode (1 of 3)
Date:________________________________________________
Location:_____________________________________________
Local Phone No.: (
)______________________________
Device:______________________________________________
Local Address:_________________________________________
DBM Installed
Serial No.:____________________________________________
Tributary Network Address:_______________________________
SNA Diagnostic Interface (LPDA-2) Installed
MUX Setup
Value
MUX Funct:
(MCMP)
TDM, MCMP, CBrdg, EBrdg, None
Share DevA:
Enab, Disab
Lowest Port #:
1, 2, 3, 4, 5
#Ports in Gp:
2, 3, 4, 5, 6
Port Cntrl:
Host, DSD
Share DevB:
Enab, Disab
Lowest Port #
1, 2, 3, 4, 5
#Ports in Gp:
2, 3, 4, 5, 6
Port Cntrl:
Host, DSD
P1/2 FEPSh:
Enab, Disab
P3/4 FEPSh:
Enab, Disab
P5/6 FEPSh:
Enab, Disab
MCMP Bckup*
MCMP, TDM
*Switched 56 DBM only
**Available for MCMP/Flex with DSU firmware version 6.3
x or greater
Prt3 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
Antistream
(Chang)
Disab, 1–100 sec
(async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
Prt1 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
Antistream
(Chang)
Disab, 1–100 sec
(async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
Prt4 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
Antistream
(Chang)
Disab, 1–100 sec (async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
Prt2 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
Antistream
(Chang)
Disab, 1–100 sec
(async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
Prt5 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
Antistream
(Chang)
Disab, 1–100 sec (async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB41 70 Notices...
Страница 22: ...COMSPHERE 3600 Series Data Service Units 1 10 July 1999 3610 A2 GB41 70...
Страница 47: ...Model 3611 Installation 3 9 3610 A2 GB41 70 July 1999 Figure 3 3 Non Modular TDM or MCMP Installation...
Страница 52: ...COMSPHERE 3600 Series Data Service Units 3 14 July 1999 3610 A2 GB41 70...
Страница 64: ...COMSPHERE 3600 Series Data Service Units 4 12 July 1999 3610 A2 GB41 70 Figure 4 8 Digital Sharing...
Страница 67: ...Principles of Operation 4 15 3610 A2 GB41 70 July 1999 Figure 4 10 FEP Port Sharing...
Страница 91: ...Principles of Operation 4 39 3610 A2 GB41 70 July 1999 Figure 4 31 Multipoint DDS Circuit in Partial Backup...
Страница 93: ...Principles of Operation 4 41 3610 A2 GB41 70 July 1999 Figure 4 33 Tributary Addressing via Backup Connections...
Страница 102: ...COMSPHERE 3600 Series Data Service Units 4 50 July 1999 3610 A2 GB41 70 Figure 4 38 Bridged LADS Operation...
Страница 111: ...Principles of Operation 4 59 3610 A2 GB41 70 July 1999 Figure 4 47 Digital Sharing in a Multipoint Circuit...
Страница 113: ...Principles of Operation 4 61 3610 A2 GB41 70 July 1999 Figure 4 49 Digital Sharing in an MCMP Circuit LPDA 2 Monitoring...
Страница 114: ...COMSPHERE 3600 Series Data Service Units 4 62 July 1999 3610 A2 GB41 70...
Страница 140: ...COMSPHERE 3600 Series Data Service Units 5 26 July 1999 3610 A2 GB41 70 Figure 5 10 Digital Test...
Страница 149: ...DSU Operations 5 35 3610 A2 GB41 70 July 1999 Figure 5 13 Choosing Mode of Operation and Setting Configuration Options...
Страница 161: ...A 1 3610 A2 GB41 70 July 1999 Data Service Unit Menu A...
Страница 162: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB41 70...
Страница 163: ...Data Service Unit Menu A 3 3610 A2 GB41 70 July 1999...
Страница 164: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB41 70...
Страница 166: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB41 70 This page intentionally left blank...
Страница 170: ......
Страница 174: ......
Страница 196: ...COMSPHERE 3600 Series Data Service Units C 18 July 1999 3610 A2 GB41 70...
Страница 230: ...COMSPHERE 3600 Series Data Service Units D 34 July 1999 3610 A2 GB41 70...