Installing the Model 3550 DSU
2-7
3550-A2-GB20-40
July 1999
Connecting to the DDS (or LADS) Network
NOTE
Before connecting the DSU to
the DDS network, ensure that
approved primary protectors
have been installed on the
circuit in accordance with Article
800 of the National Electric
Code, NFPA 70, in the United
States and Section 60 of the
Canadian Electric Code, Part 1,
in Canada.
Refer to Figure 2-5 as you follow these steps.
"
Procedure
1. Plug the DDS network interface cable into the
DSU jack labeled LINE.
•
U.S. – select either end of the cable
•
Canada – select the 8-pin end
2. Plug the other end of the cable into the modular
jack (USOC RJ48S) provided by the circuit
provider.
If the remote DSU is also connected to the network, the
DSU’s green OK indicator lights and the Alrm indicator
goes off. The Health and Status screen no longer displays
a No Signal message.
If connecting the DSU to a LADS network, there are
distance limitations that govern the use of DSUs on the
network.
Table 2-2
summarizes these limitations.
Figure 2-5. Model 3550 DSU DDS (LADS)
Network Connection
Содержание Comsphere 3551
Страница 4: ...COMSPHERE 3550 Series Data Service Units C July 1999 3550 A2 GB20 40 Notices ...
Страница 12: ...COMSPHERE 3550 Series Data Service Units vi July 1999 3550 A2 GB20 40 ...
Страница 68: ...COMSPHERE 3550 Series Data Service Units 4 22 July 1999 3550 A2 GB20 40 ...
Страница 98: ...COMSPHERE 3550 Series Data Service Units 5 30 July 1999 3550 A2 GB20 40 ...
Страница 100: ...COMSPHERE 3550 Series Data Service Units A 2 July 1999 3550 A2 GB20 40 ...
Страница 101: ...DSU Menu A 3 3550 A2 GB20 40 July 1999 ...
Страница 108: ...COMSPHERE 3550 Series Data Service Units B 6 July 1999 3550 A2 GB20 40 ...
Страница 122: ...COMSPHERE 3550 Series Data Service Units C 14 July 1999 3550 A2 GB20 40 ...
Страница 129: ...Pin Assignments D 7 3550 A2 GB20 40 July 1999 Figure D 5 EIA 232 D Crossover Cable 4951 035F ...
Страница 134: ...COMSPHERE 3550 Series Data Service Units E 4 July 1999 3550 A2 GB20 40 ...