COMSPHERE 3550 Series Data Service Units
2-8
July 1999
3550-A2-GB20-40
Table 2-2
LADS Connection Distances
Data Rate
Wire Gauge (AWG)
Data Rate
(kbps)
19
22
24
26
2.4
20.0 mi
(32.2 km)
16.6 mi
(26.7 km)
12.7 mi
(20.5 km)
9.4 mi
(15.1 km)
4.8
19.4 mi
(31.2 km)
12.7 mi
(20.5 km)
9.6 mi
(15.4 km)
7.1 mi
(11.5 km)
9.6
15.2 mi
(24.5 km)
9.7 mi
(15.6 km)
7.3 mi
(11.7 km)
5.6 mi
(9.0 km)
19.2
1
11.8 mi
(19.0 km)
7.5 mi
(12.1 km)
5.7 mi
(9.2 km)
4.2 mi
(6.8 km)
38.4
11.2 mi
(18.0 km)
6.5 mi
(10.5 km)
4.6 mi
(7.4 km)
3.2 mi
(5.1 km)
56
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
6.2 km)
2.8 mi
(4.5 km)
64
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
(6.2 km)
2.8 mi
4.5 km)
1
Power level is –10 dBm.
Addressing the Unit
A unique address must be assigned to each control and
tributary DSU in your network. You can assign an address
within the range of 1 through 255.
NOTE
Do not assign the number 192
as a network address. This
number is reserved as a
broadcast address.
If a DBM is installed, it requires a separate address
which is automatically assigned by the DSU. The address
assigned a DBM is the DSU’s address, plus 1 (e.g., if the
DSU’s address is 1, the assigned DBM address will be 2).
NOTE
The numbers 191 and 255
cannot be assigned to a DSU
that has a DBM. However,
addresses can be assigned in
any order; they do not have to be
sequential.
It is recommended that only
odd-numbered addresses be
assigned to DSUs so that
even-numbered addresses are
reserved for DBMs
. If your
network does not currently
include DBMs, you retain the
flexibility to add them later
without having to reconfigure
your entire network.
Содержание Comsphere 3551
Страница 4: ...COMSPHERE 3550 Series Data Service Units C July 1999 3550 A2 GB20 40 Notices ...
Страница 12: ...COMSPHERE 3550 Series Data Service Units vi July 1999 3550 A2 GB20 40 ...
Страница 68: ...COMSPHERE 3550 Series Data Service Units 4 22 July 1999 3550 A2 GB20 40 ...
Страница 98: ...COMSPHERE 3550 Series Data Service Units 5 30 July 1999 3550 A2 GB20 40 ...
Страница 100: ...COMSPHERE 3550 Series Data Service Units A 2 July 1999 3550 A2 GB20 40 ...
Страница 101: ...DSU Menu A 3 3550 A2 GB20 40 July 1999 ...
Страница 108: ...COMSPHERE 3550 Series Data Service Units B 6 July 1999 3550 A2 GB20 40 ...
Страница 122: ...COMSPHERE 3550 Series Data Service Units C 14 July 1999 3550 A2 GB20 40 ...
Страница 129: ...Pin Assignments D 7 3550 A2 GB20 40 July 1999 Figure D 5 EIA 232 D Crossover Cable 4951 035F ...
Страница 134: ...COMSPHERE 3550 Series Data Service Units E 4 July 1999 3550 A2 GB20 40 ...