Installing the Model 3550 DSU
2-3
3550-A2-GB20-40
July 1999
496-14457-01
SWITCH 1
HINGE TAB
LOCATIONS
FRONT BEZEL
COMSPHERE
3550
SNAP
TABS
Figure 2-1. Model 3550 Hardware Switch Location (shown without a TDM/Flex)
Table 2-1
Model 3550 DSU Switch Settings
Switch Position
Switch Setting
Function
S1-1
ON
(default)
Permissive V.32 DBM transmit output level of –9 dBm
S1-1
Off
Programmable V.32 DBM transmit level between –12 dBm and 0 dBm
ON
Frame ground (FG) connected to signal ground (SG)
S1-2
Off
(default)
FG connected to SG through 100 ohm resistor
ON is to the rear as you face the front of the DSU.
Off is to the front.