NoWire CellConnect™ GSM Modem Installation Notes 

 

These instructions show you how to connect up the CellConnect GSM Modem to the NoWire equipment as well 
as configure it for use in your system.   
 
Note: NoWire COM2 can only have the GSM Modem mode operating or Modbus Slave RTU mode operating, 
Not both at the same time. 
 
 

Safety and Static Protection: 

 
During this procedure remove power from NoWire and the GSM modem.  The NoWire circuit board has 
statically sensitive components.  Though the circuitry is robust avoid static electrical charges whenever possible.  
When handling NoWire, whenever possible, hold the circuit board by the edges to avoid touching the 
components.  Perform this procedure in a low static environment…not on carpet, not wearing nylon clothing, etc.  
Discharge any static charges on your body by touching the grounded center screw on a standard electrical 
outlet.  If possible wear an anti-static wrist strap. 
 

Installation Instructions: 

 
1. Remove the blue cover then remove the 4 mounting screws on the corners of the NoWire circuit board.  
Remove the NoWire circuit board from the case. 
 

 

 
2. Remove the access plug from the bottom of the NoWire case.  Locate the NoWire-GSM serial cable and 
carefully push the connector through the plug being careful not pulling out the wires from the connector.  Go 
slowly and wiggle it attempting to minimize stress on the wires. 
 

 

 

Содержание NoWire CellConnect

Страница 1: ...atic electrical charges whenever possible When handling NoWire whenever possible hold the circuit board by the edges to avoid touching the components Perform this procedure in a low static environment not on carpet not wearing nylon clothing etc Discharge any static charges on your body by touching the grounded center screw on a standard electrical outlet If possible wear an anti static wrist stra...

Страница 2: ...components on the circuit board by holding the board by its edges 5 Place the NoWire circuit board back in the case laying it down on top of the cable Don t force it Adjust the cable under the circuit board so it doesn t bind on the components and metal antenna of the receiver board underneath Screw back in the mounting screws to attach the NoWire circuit board back into the case 6 Re apply all ot...

Страница 3: ...ions com 8 Flip the GSM modem over and slide the mounting tabs into the slot on the bottom of the case Flip it back over and screw the tabs into the wall to securely mount GSM modem in a location that can be received by the cellular network usually right next to the NoWire enclosure works 9 Apply power to NoWire and the GSM Modem ...

Страница 4: ...en flow will move to the System Items in the setup menu BACK CHANGE to view Current GSM Modem Status After initialization during startup it should eventually display Loop Chk Signal and Loop Chk Network The last error and the time it occurred as seen by the GSM Modem Cycling power on NoWire will clear this field Used for troubleshooting The cellular phone number of the GSM Modem A Zero number indi...

Отзывы: