ACCULINK 3360, 3364, and 3365 E1 NTU
4-4
March 1999
3360-A2-GB20-30
Table 4-2
(2 of 2)
Health and Status Messages
Message
Description
EER at DTE
An Excessive Error Rate condition has been detected on the G.703 DTE interface. The condition is
cleared when the error rate falls below the threshold value (10
-4
) for 5 seconds.
RAI at Net
A Remote Alarm Indication is being received by the network interface.
RAI at DTE
A Remote Alarm Indication is being received by the G.703 DTE interface.
MFA at Net
A Multiframe Alarm condition (2 consecutive errored multiframe alignment signals, or two
consecutive multiframes with all zeros in time-slot 16) has been detected on the network interface.
The condition is cleared when realignment (or time-slot 16 correction) occurs.
MFA at DTE
A Multiframe Alarm condition has been detected on the G.703 DTE interface. The condition is
cleared when realignment (or time-slot 16 correction) occurs.
RMA at Net
A Remote Multiframe Alarm signal is being received by the network interface.
RMA at DTE
A Remote Multiframe Alarm signal is being received by the G.703 DTE interface.
Primary Clk fail
The primary clock has failed. Timing for the E1 NTU is provided by the secondary clock.
Second Clk fail
The primary clock and the secondary clock have failed. Timing is provided by the internal clock.
OOF at Prt
n
An Out Of Frame has been detected on data port Prt
n (where n is the port number). This condition
only occurs if the synchronous data port’s Embedded Data Link (EDL) is enabled (only available for
2-port and 4-port E1 NTUs).
EER at Prt
n
The error rate of the received signal has exceeded the configured threshold for data port Prt
n
(where
n is the port number). This condition only occurs if the synchronous data port’s Embedded
Data Link (EDL) is enabled (only available for 2-port and 4-port E1 NTUs). The condition is cleared
when the error rate falls below the synchronous data port’s configured threshold value.
PORT SNMP Down
The SNMP management link is in a down state for
PORT (where PORT is COM or AUX). This
condition occurs if the
PORT is configured for SNMP, and communication between the
management system and the E1 NTU is not currently possible for this port. For the AUX port, this
condition is detected only when a device reset or power-up occurs.
Selftest failed
A failure was detected during the power-on self-test. Select STest (in the Stat branch) to display
more information about the failure.
DevFail
xxxxxxxx
An internal error has been detected by the operating software. An 8-digit code appears for use by
service personnel. The condition is cleared by resetting the device.
Download failed
A download attempt was interrupted and failed to complete. The condition is cleared by resetting
the device.
Test in progress
A test is currently active. Select Tstat (in the Stat branch) to display more test information.
Lp1/Lp2 Reversed
The loop 1 and loop 2 connections on the HDSL network are reversed.
NTU Operational
This message only appears if the unit is configured as an NTU and there are no valid alarm or
status messages.
LTU Operational
This message only appears if the unit is configured as an LTU and there are no valid alarm or
status messages.
Содержание ACCULIN 3364
Страница 1: ...ACCULINK 3360 3364 AND 3365 E1 NTU OPERATOR S GUIDE Document No 3360 A2 GB20 30 March 1999 ...
Страница 8: ...ACCULINK 3360 3364 and 3365 E1 NTU iv March 1999 3360 A2 GB20 30 ...
Страница 16: ...ACCULINK 3360 3364 and 3365 E1 NTU 1 6 March 1999 3360 A2 GB20 30 ...
Страница 26: ...ACCULINK 3360 3364 and 3365 E1 NTU 2 10 March 1999 3360 A2 GB20 30 ...
Страница 64: ...ACCULINK 3360 3364 and 3365 E1 NTU 3 38 March 1999 3360 A2 GB20 30 ...
Страница 92: ...ACCULINK 3360 3364 and 3365 E1 NTU A 2 March 1999 3360 A2 GB20 30 ...
Страница 156: ...ACCULINK 3360 3364 and 3365 E1 NTU E 20 March 1999 3360 A2 GB20 30 ...
Страница 162: ...ACCULINK 3360 3364 and 3365 E1 NTU H 2 March 1999 3360 A2 GB20 30 ...
Страница 172: ...ACCULINK 3360 3364 and 3365 E1 NTU Glossary 10 March 1999 3360 A2 GB20 30 This page intentionally left blank ...