SNMP MIB Objects
E-19
3360-A2-GB20-30
March 1999
Table E-1
(4 of 4)
SNMP MIB to Front Panel Command Cross-Reference
Front Panel Command
SNMP MIB Object
Cnfig–>Activ–>Edit–>Chan–>DTE–>Assign
Set/Display dsx1FracNumber and dsx1FracIfindex for DTE E1
Cnfig–>Activ–>Edit–>Chan–>DTE–>TS16
Display dsx1SignalMode for DTE E1 to
none or bitOriented or
messageOriented
Cnfig–>Activ–>Edit–>Chan–>Prt
n–>Assign To
Cnfig–>Activ–>Edit–>Chan–>Dsply
Set/Display dsx1FracNumber and dsx1Fracifindex for DTE E1 or
NET E1
Cnfig–>Activ–>Edit–>Chan–>Prt
n–>Port Rate
Display rs232PortInSpeed or rs232PortOutSpeed for port
n
Cnfig–>Activ–>Edit–>Gen–>Pri Clk Src
Cnfig–>Activ–>Edit–>Gen–>Sec Clk Src
Display dsx1TransmitClockSource for DTE E1 or NET E1 (Displays
the active clock only)
Cnfig–>Activ–>Edit–>User–>Com Rate
Cnfig–>Activ–>Edit–>User–>Aux Rate
Set/Display rs232PortInSpeed or rs232PortOutSpeed for COM or
AUX port
Cnfig–>Activ–>Edit–>User–>Char Length
Set/Display rs232AyncPortBits for COM port
Cnfig–>Activ–>Edit–>User–>CParty
Set/Display rs232AyncPortParity for COM port
Cnfig–>Activ–>Edit–>User–>CStop Bits
Set/Display rs232AyncPortStopBits for COM port
Содержание ACCULIN 3364
Страница 1: ...ACCULINK 3360 3364 AND 3365 E1 NTU OPERATOR S GUIDE Document No 3360 A2 GB20 30 March 1999 ...
Страница 8: ...ACCULINK 3360 3364 and 3365 E1 NTU iv March 1999 3360 A2 GB20 30 ...
Страница 16: ...ACCULINK 3360 3364 and 3365 E1 NTU 1 6 March 1999 3360 A2 GB20 30 ...
Страница 26: ...ACCULINK 3360 3364 and 3365 E1 NTU 2 10 March 1999 3360 A2 GB20 30 ...
Страница 64: ...ACCULINK 3360 3364 and 3365 E1 NTU 3 38 March 1999 3360 A2 GB20 30 ...
Страница 92: ...ACCULINK 3360 3364 and 3365 E1 NTU A 2 March 1999 3360 A2 GB20 30 ...
Страница 156: ...ACCULINK 3360 3364 and 3365 E1 NTU E 20 March 1999 3360 A2 GB20 30 ...
Страница 162: ...ACCULINK 3360 3364 and 3365 E1 NTU H 2 March 1999 3360 A2 GB20 30 ...
Страница 172: ...ACCULINK 3360 3364 and 3365 E1 NTU Glossary 10 March 1999 3360 A2 GB20 30 This page intentionally left blank ...