Configuration Options
C-3
3360-A2-GB20-30
March 1999
Port Configuration Options
Table C-2
(1 of 4)
Port Configuration Options
Port Type: E530
Next E530 V.35 RS449 X.21 Prev
Data Port Type. Allows selection of the data port interface type.
E530 – Configures the port as an EIA-530-A compatible interface. EIA-530-A DTEs can be directly connected to a port
connector on the back of the E1 NTU.
V.35 – Configures the port as a V.35 compatible interface. V.35 DTEs can be connected to a port connector using an
EIA-530-A-to-V.35 adapter.
RS449 – Configures the port as an RS449 compatible interface. RS449 DTEs can be connected to a port connector using
an EIA-530-A-to-RS-449 adapter.
X.21 – Configures the port as an X.21 compatible interface. X.21 DTEs can be connected to a port connector using an
EIA 530A-to-X.21 adapter.
NOTE: If this configuration option is set to X.21, you must set the All Ones configuration option to RTS or Disab.
Net DCLB: Disab
Next Enab Disab Prev
Network Initiated DCLB. Allows the initiation and termination of a Data Channel Loopback (V.54 loop 2) by the receipt of a
V.54 DCLB-actuate sequence or DCLB-release sequence from the network or far-end device.
Enab – Allows the E1 NTU to begin a DCLB for this port when it receives a DCLB-actuate sequence (if the current E1
NTU state allows a DCLB to be performed). Receiving a DCLB-release sequence terminates the DCLB.
Disab – Ignores the DCLB-actuate and DCLB-release sequences for this port.
Port LB: Disab
Next Disab DTLB DCLB Both Prev
Port (DTE) Initiated Loopbacks. Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or remote
Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB is equivalent to a V.54 loop 3, and DCLB is
equivalent to a V.54 loop 2.) Control of these loopbacks is through the DTE interchange circuits as specified by the V.54
standard.
Disab – Disables control of local DTLBs and remote DCLBs by the DTE connected to this port.
DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port. This loopback is controlled by the
Local Loopback interchange circuit LL (ITU-T 141).
DCLB – Gives control of the remote DCLBs for the far-end port connected to this port to the DTE attached to this port.
This loopback is controlled by the Remote Loopback interchange circuit RL (ITU-T 140). The far-end equipment must
support in-band V.54 loopbacks.
Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to this port.
Содержание ACCULIN 3364
Страница 1: ...ACCULINK 3360 3364 AND 3365 E1 NTU OPERATOR S GUIDE Document No 3360 A2 GB20 30 March 1999 ...
Страница 8: ...ACCULINK 3360 3364 and 3365 E1 NTU iv March 1999 3360 A2 GB20 30 ...
Страница 16: ...ACCULINK 3360 3364 and 3365 E1 NTU 1 6 March 1999 3360 A2 GB20 30 ...
Страница 26: ...ACCULINK 3360 3364 and 3365 E1 NTU 2 10 March 1999 3360 A2 GB20 30 ...
Страница 64: ...ACCULINK 3360 3364 and 3365 E1 NTU 3 38 March 1999 3360 A2 GB20 30 ...
Страница 92: ...ACCULINK 3360 3364 and 3365 E1 NTU A 2 March 1999 3360 A2 GB20 30 ...
Страница 156: ...ACCULINK 3360 3364 and 3365 E1 NTU E 20 March 1999 3360 A2 GB20 30 ...
Страница 162: ...ACCULINK 3360 3364 and 3365 E1 NTU H 2 March 1999 3360 A2 GB20 30 ...
Страница 172: ...ACCULINK 3360 3364 and 3365 E1 NTU Glossary 10 March 1999 3360 A2 GB20 30 This page intentionally left blank ...