SNMP Traps
C-4
9161-A2-GH30-40
April 1999
Traps: Enterprise-Specific
These traps indicate that an enterprise-specific event has occurred. Supported
enterprise-specific traps include the following, listed in alphabetical order:
Trap
What It Indicates
Possible Cause
enterpriseAPMFailed(9)
The APM cannot be detected.
The APM has failed or has been
removed.
enterpriseAPMFailedClear (109)
The APM failure has cleared.
The APM failure has cleared.
enterpriseConfigChange(6)
Configuration has been changed
via the user interface or an SNMP
Manager after 60 seconds has
elapsed without another change.
Configuration has been changed
via the user interface or an SNMP
Manager.
enterpriseDeviceFail(3)
An internal device failure.
Operating software has detected
an internal device failure.
enterpriseModuleMisConfig (8)
A module misconfiguration has
been detected.
An APM is installed in a slot that
previously contained another type
of APM.
enterpriseModuleMisConfigClear(108)
A module misconfiguration error
condition has been cleared.
The operating software no longer
detects a misconfiguration.
enterprisePowerSupply(7)
The power supply output voltage
has dropped below the tolerance
level.
Power supply problem.
enterprisePowerSupplyClear(107)
The power supply output voltage
alarm condition has cleared.
The power supply output voltage
alarm condition has cleared.
enterprisePrimaryClockFail(1)
A failure of the device’s currently
configured primary clock source.
Operating software has detected
that the primary clock source has
failed.
enterprisePrimaryClockFailClear(101)
The failure of the device’s currently
configured primary clock source
has cleared.
Operating software has detected
that the primary clock source is
now operational again.
enterpriseSecondaryClockFail(4)
A failure of the device’s currently
configured secondary clock
source.
Operating software has detected
that the secondary clock source
has failed.
enterpriseSecondaryClockFailClear(104)
The failure of the device’s currently
configured secondary clock source
has cleared.
Operating software has detected
that the secondary clock source is
now operational again.
enterpriseSelfTestFail(2)
A hardware failure.
Unit has completed (re)initialization
and a hardware failure was
detected.
enterpriseTestStart(5)
A test is running.
At least one test has been started
on an interface.
enterpriseTestStop(105)
All tests have been halted.
All tests have been halted on an
interface.
Содержание 9261
Страница 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 40 April 1999 ...
Страница 14: ...Contents viii 9161 A2 GH30 40 April 1999 F Technical Specifications G Equipment List Glossary Index ...
Страница 34: ...Management and Control 2 6 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Страница 54: ...User Interface 4 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Страница 92: ...Setting Up 5 38 9161 A2 GH30 40 April 1999 Example Channel Allocation ...
Страница 142: ...Security 6 10 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Страница 168: ...Displaying System Information 7 26 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Страница 244: ...Menus and Configuration Worksheets A 18 9161 A2 GH30 40 April 1999 This page intentionally left blank ...
Страница 252: ...IP Addressing B 8 9161 A2 GH30 40 April 1999 This page intentionally left blank ...