background image

Spectra Keypads 41

026:_____________

____

N

N

N

N

N

027:_____________

____

N

N

N

N

N

028:_____________

____

N

N

N

N

N

029:_____________

____

N

N

N

N

N

030:_____________

____

N

N

N

N

N

031:_____________

____

N

N

N

N

N

032:_____________

____

N

N

N

N

N

033:_____________

____

N

N

N

N

N

034:_____________

____

N

N

N

N

N

035:_____________

____

N

N

N

N

N

036:_____________

____

N

N

N

N

N

037:_____________

____

N

N

N

N

N

038:_____________

____

N

N

N

N

N

039:_____________

____

N

N

N

N

N

040:_____________

____

N

N

N

N

N

041:_____________

____

N

N

N

N

N

042:_____________

____

N

N

N

N

N

043:_____________

____

N

N

N

N

N

044:_____________

____

N

N

N

N

N

045:_____________

____

N

N

N

N

N

User # and Name

Partition

1 or 2

Byp Stay Force

Arm 

Only

PGM 
Only

http://www.ealarm.com.my

Содержание Spectra 1689

Страница 1: ...LCD and 16 Zone LED Keypads 1689 1641 16 Zone LED Keypad LCD Keypad User s Manual h t t p w w w e a l a r m c o m m y...

Страница 2: ...ay 9 2 7 Partitioning 13 3 0 PROGRAMMING ACCESS CODES 14 3 1 System Master Code Default 123456 14 3 2 Master Codes 14 3 3 Duress Code 15 3 4 Programming Access Codes 15 4 0 ARMING DISARMING 17 4 1 Exi...

Страница 3: ...ting 29 5 3 Panic Alarms 30 5 4 Program Time clock 30 5 5 PGM Button Programmable Outputs 31 5 6 Quick Function Keys 31 5 7 Keypad Settings For LCD Keypads only 32 6 0 FIRE ALARMS 33 7 0 TESTING MAINT...

Страница 4: ...anyone can use without memorizing complex and confusing codes The system consists of the Spectra Control Panel one or more Spectra Keypads various input devices i e motion detectors door contacts etc...

Страница 5: ...ion beep and the action will be cancelled Refer to System Checklist in section 8 0 for details 2 1 KEYPAD INDICATOR LIGHTS The state of each light on the Spectra Keypads represents a specific conditio...

Страница 6: ...FEEDBACK 2 2 1 For the Spectra 1689 LED Keypad The numbers and symbols on the keypad s screen communicate your system s status as shown in Figure 2 2 Figure 2 2 Overview of the 1689 LED Keypad h t t p...

Страница 7: ...it will guide you with beep tones You should be familiar with these Confirmation Beep When an operation i e arming disarming is successfully entered on the keypad or when the system switches to a new...

Страница 8: ...rming the system press the MEM button to illuminate the number symbols corresponding to the zones that were in alarm To exit the Alarm Memory Display press the CLEAR button For Spectra 1641 LCD Keypad...

Страница 9: ...e 2 4 Once you enter the Event List the time the event occurred and what event occurred will scroll on the screen As you press the V button the next pair will scroll Figure 2 4 Example of Event Screen...

Страница 10: ...5 seconds whenever a new trouble condition has occurred Press the TRBL button to stop the Trouble Beep For Spectra 1689 LED Keypad When a trouble condition occurs the TRBL symbol will illuminate How D...

Страница 11: ...ackup battery is disconnected or the battery voltage is getting low 2 Wireless Transmitter Battery Low The battery voltage in one or more Wireless Transmitters is getting low Also the device s yellow...

Страница 12: ...t will automatically shut down if the current exceeds a predetermined value When the system is disarmed the current is cut from the bell output and the Trouble warning may extinguish but the Trouble m...

Страница 13: ...wiring problem on the fire zone is occurring 12 Module Loss A module is no longer communicating with your system To re program the clock press the 8 button after Step 2 from the Trouble Display see Ho...

Страница 14: ...hat can divide your alarm system into two distinct areas identified as Partition 1 and Partition 2 Partitioning can be used in installations where shared security systems are more practical such as a...

Страница 15: ...hecklist in section 8 0 3 1 SYSTEM MASTER CODE Default 123456 The System Master Code can arm or disarm any partition using any of the methods described in this section and can create modify or delete...

Страница 16: ...the Access Code assigned to User 048 will arm or disarm the system and immediately transmit a silent alert Duress Code to the Security Company Must be enabled by your installer 3 4 PROGRAMMING ACCESS...

Страница 17: ...to exit How Do I Delete Access Codes 1 Repeat steps 1 to 3 see above 2 Press the FORCE button once for each digit in the Access Code 4 or 6 times until the keypad emits a CONFIRMATION BEEP then press...

Страница 18: ...the Exit Delay 4 2 DISARMING DEACTIVATING AN ALARM To disarm an armed system or an alarm enter your access code An entry point like the front door will be programmed with one of two Entry Delay Timers...

Страница 19: ...try point i e front door 2 Enter your ACCESS CODE IF YOU HAVE ACCESS TO BOTH PARTITIONS see section 2 7 3 Press the button corresponding to the desired partition 1 or 2 For both partitions press the o...

Страница 20: ...tectors Stay Arming can also be activated using Auto Arming see section 4 9 a Keyswitch see section 4 8 or One Touch Arming see section 4 7 How Do I Stay Arm 1 Close all zones in the desired partition...

Страница 21: ...d zone that is breached will immediately generate an alarm If you have access to both partitions To Instant Arm one partition 1 Press the STAY button 2 Enter your ACCESS CODE 3 Choose a partition 4 Pr...

Страница 22: ...mple when arming and the motion detector is a Force Zone the system will allow you to arm even if the zone is open Force Arming can also be activated by using One Touch Force Arming see section 4 7 6...

Страница 23: ...When zones are bypassed the BYP symbol will illuminate Manual Bypass Programming can also be activated by using One Touch Bypass Programming see section 4 7 7 To remove the Bypass feature from a zone...

Страница 24: ...1 or 2 4 6 2 Bypass Recall Feature After disarming the system the bypass entries are erased The Bypass Recall Feature reinstates the previous bypass entries saved in memory This eliminates the need to...

Страница 25: ...er alarm system operations For details on Regular Arming refer to section 4 3 4 7 4 One Touch Stay Arming Press and hold the STAY button for 3 seconds see Note1 p 23 to arm all zones not defined as St...

Страница 26: ...gular Arming see section 4 3 Exit and Force Arm Press and hold the FORCE button for 3 seconds see Note1 p 23 to start the Exit Delay see section 4 1 When the Exit Delay elapses the system will switch...

Страница 27: ...tch set the keyswitch to the on position To disarm the system set the keyswitch to the off position To arm the system using a Momentary Keyswitch set the keyswitch to the on position then turn it back...

Страница 28: ...can be programmed to arm the system and or send a report if no zone activity occurs for a pre programmed amount of time This is a particularly useful feature when supervising an individual with chron...

Страница 29: ...he number extinguishes or press FORCE to remove Chiming from all zones programmed to Chime When you program Chime Zones once you press and hold the 9 button the ARM1 STAY1 ARM2 STAY2 BYP MEM and TRBL...

Страница 30: ...sed Therefore when muted the keypad will not beep during an alarm Press and hold the CLEAR button for 3 seconds to enable or disable Keypad Muting If the keypad emits a confirmation beep Keypad Muting...

Страница 31: ...an communicate specific messages to your monitoring station For instance pressing 1 3 can mean call the police or anything you require Press hold buttons 1 and 3 for the police Press hold buttons 4 an...

Страница 32: ...3 seconds 5 6 QUICK FUNCTION KEYS Upon request of your installer or Security Company you may have to perform one of the following Press 5 6 1 Test Report ENTER MASTER CODE MEM If your system is monito...

Страница 33: ...pads only You can modify the keypad s setting to suit your needs 1 Press hold 6 for 3 seconds 2 Choose one Press 1 Backlight the keypad s light 7 is the brightest 2 Contrast character intensity 7 is t...

Страница 34: ...porting of false alarms If there is no fire condition contact your Security Company immediately to avoid an unnecessary response What do I do if a Delayed Fire Zone was set off accidentally 1 Press th...

Страница 35: ...of the report delayed for 30 seconds Has CLEAR been pressed within 30 seconds Bell siren silenced Report transmission delayed an additional 90 seconds Problem corrected Generate alarm and alert Securi...

Страница 36: ...since the heating systems in single family homes are often not professionally maintained Fire Safety Tips In the event of a fire remember time is the biggest enemy and every second counts Escape first...

Страница 37: ...smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the bedroo...

Страница 38: ...t way to test your particular system Do not use open flame or burning materials to test your fire detection devices Contact your installer for safe methods of testing your system Under normal use your...

Страница 39: ...Stay Force 24Hr Entry Delay 01 _______________ ____ N N N N N 02 _____________ Keyswitch Y N N N Type ____________ ____ N N N N N 03 ______________ Fire Zone Y N N N Delayed Y N N N ____ N N N N N 04...

Страница 40: ..._____________ ____ N N N N N 15 _______________ ____ N N N N N 16 _______________ ____ N N N N N User and Name Partition 1 or 2 Byp Stay Force Arm Only PGM Only 001 ____________ System Master Code Def...

Страница 41: ...__________ ____ N N N N N 015 _____________ ____ N N N N N 016 _____________ ____ N N N N N 017 _____________ ____ N N N N N 018 _____________ ____ N N N N N 019 _____________ ____ N N N N N 020 _____...

Страница 42: ...___________ ____ N N N N N 035 _____________ ____ N N N N N 036 _____________ ____ N N N N N 037 _____________ ____ N N N N N 038 _____________ ____ N N N N N 039 _____________ ____ N N N N N 040 ____...

Страница 43: ...N Audible N Off 4 6 Aux or ___________ N Silent N Audible N Off 7 9 Fire or ___________ N Silent N Audible N Off PGMs PGM 1 ___________________________________________ PGM 2 __________________________...

Страница 44: ...isarm before alarm enter through zone ___________ Alarm will activate siren or bell for ______ min Other Information Installed by __________________ Date ______________ Serviced by __________________...

Страница 45: ...mmed digit will illuminate and so forth For example if you wish to change User Code 004 from 123456 to 454545 after entering section 004 number 1 will turn on Press the 4 button and number 2 will turn...

Страница 46: ...oducts not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at S...

Страница 47: ...h t t p w w w e a l a r m c o m m y...

Отзывы: