24
Reference & Installation Manual
Alarm Options
Bell Cut-off Timer
Section [063]: 001 to 255 minutes; 000 = Disabled; Default = 4
minutes
After an audible alarm, the siren will stop upon the disarming of
the system or when the Bell Cut-Off timer has elapsed,
whichever comes first.
Wireless Transmitter Supervision Options
Section [094]: Options [6] and [7]
This feature determines how the Magellan console will react to a
Supervision Loss trouble. Table 4 shows the different
Supervision Loss combinations available and how the system
will react when armed or disarmed.
In UL installations, if a zone is used as a fire zone, the zone
must be supervised and the check-in supervision time must be
set to 80 minutes.
Table 4: Wireless Transmitter Supervision Options
Supervision Bypass Options
Section [094]: Option [8]
Option [8] OFF = No Supervision Loss if detected on a
bypassed zone (default)
Option [8] ON =
Generate Supervision Loss if detected on a
bypassed zone
•
When option [8] is OFF, the Wireless Transmitter
Supervision Options (see page 24) will follow the zone's
bypass definition. This means the console will not perform
any action if a Supervision Loss occurs on a bypassed zone.
•
When option [8] is ON, the Wireless Transmitter Supervision
Options (see page 24) will ignore the bypass definition. This
means the console will generate an incident as per the set
Wireless Transmitter Supervision Option if a Supervision
Loss occurs on a bypassed zone.
Check-in Supervision Options
Section [290]: Options [1] to [8]; Zones 1 to 8; Default: All ON
Section [291]: Options [1] to [8]; Zones 9 to 16; Default: All ON
Section [292]: Options [1] to [8]; Zones 17 to 24; Default: All ON
Section [293]: Options [1] to [8]; Zones 25 to 32; Default: All ON
If enabled, Magellan can wait for each of its assigned wireless
transmitters to send a status signal within a specified time (see
Check-in Supervision Time on page 24) to confirm their
presence and functionality. If a device has not sent a signal
within the specified time period, Magellan can generate a
trouble, an alarm and/or transmit a report code to the monitoring
station as defined by the Wireless Transmitter Supervision
Options (see page 24). Sections [190] and [193] determine
which zones will be supervised and which will not. Enable the
option pertaining to the zone you wish Magellan to supervise.
This feature must be enabled in UL installations.
Check-in Supervision Time
Section [096]: Option [7]
Option [7] OFF = Check-in Supervision Time = 24Hrs (default)
Option [7] ON =
Check-in Supervision Time = 80 minutes
Section [096] option [7] defines the time period that Magellan will
expect a check-in status signal from the specified wireless
transmitters as defined in the Check-in Supervision Options (see
page 24). If no signal is received within the check-in supervision
time, Magellan’s reaction will be defined by the Wireless
Transmitter Supervision Options (see page 24).
In UL installations, if a zone is used as a fire zone, the zone
must be supervised and the check-in supervision time must be
set to 80 minutes.
Tamper Recognition Options
Section [094]: Options [3] and [4]
This feature determines how the Magellan console will react to a
zone tamper. Table 5 on page 25 shows the different Tamper
Recognition combinations available and how the system will
react when armed or disarmed.
Options
Description
[6]
[7]
OFF
OFF
Wireless transmitter supervision disabled
OFF
ON
Trouble only (default)
System armed or disarmed: If a Supervision Loss
occurs on a zone, the console will display a trouble on
the LCD screen and send a report to the monitoring
station (if programmed).
ON
OFF
Audible alarm when armed
System armed: If a Supervision Loss occurs on a
zone, the console will follow the zone's Alarm Types
setting (see page 17).
System disarmed: If a Supervision Loss occurs on a
zone, the console will display a trouble on the LCD
screen and send a report to the monitoring station (if
programmed).
ON
ON
Audible alarm
System armed: If a Supervision Loss occurs on a
zone, the console will follow the zone's Alarm Types
setting (see page 17).
System disarmed: It functions the same as Trouble
Only setting, except it will also generate an audible
alarm.
Содержание MG-6130
Страница 2: ......