Alarm Display
If an alarm has occurred on a zone, the respective zone LED will flash, the
[
MEM
]
key will light up, and the zones will be stored in
memory.
These respective LEDs will continue to flash until disarming even if the zones are restored. To exit this mode and switch
to live display mode before disarming, press the
[
CLEAR
]
key. Once the system is disarmed, the zones’ LEDs will turn off, while
the
[
MEM
]
key remains lit. Press the
[
MEM
]
key to illuminate the LEDs corresponding to the zones that were in alarm. The alarm
memory will be erased when the next alarm occurs and after a valid code is entered or upon full-arming the system.
16.2
Trouble Display
Press the
[
TBL
]
key to view the Trouble Display. Please note that the keypad can be programmed to emit a beep every 5 seconds
whenever a new trouble condition has occurred. Press the
[
TBL
]
key to stop the beeping.
To view the sub-menu, press the corresponding key in the main menu.
Main Menu Trouble
Sub-Menu Trouble Menu
[1]
Wireless zone low battery
[1]
to
[32]
Zones in low battery
[2]
Power trouble
[1]
Low/No battery on the control panel
[2]
AC failure on control panel
[3]
Auxiliary overload on control panel
[4]
Wireless keypad AC failure
[5]
Wireless keypad battery failure
[6]
Wireless repeater AC failure
[7]
Wireless repeater battery failure
[3]
Bell trouble
[1]
Bell disconnect on control panel
[2]
Bell overload on control panel
[4]
Communication trouble
[1]
Telephone Line Monitoring on control panel
[2]
Fail to communicate on Monitoring Telephone 1 on control panel
[3]
Fail to communicate on Monitoring Telephone 2 on control panel
[4]
Fail to communicate on pager telephone on control panel
[5]
Fail to communicate on voice telephone on control panel
[6]
Fail to communicate with PC on control panel
[5]
Tamper and zone wiring failure
[1]
to
[32]
Zones in tamper and zone wiring failure
[6]
Module tamper trouble
[1]
2WPGM
[2]
Keypad bus
[3]
ZX8 Bus Module
[4]
RTX3 Bus Module
[5]
Wireless keypad
[7]
Fire loop trouble
[1]
to
[32]
Zones in fire loop trouble
[8]
Timer loss
[9]
Wireless zone supervision loss
[1]
to
[32]
Zones in supervision lost6
[
STAY
]
RF interference trouble
[0 (10)] or [10]
Module supervision loss
[1]
2WPGM
[2]
Keypad bus (Panel reset will not clear this trouble, clear it in
section
[955]
)
[3]
ZX8 Bus Module
[4]
RTX3 Bus Module
[5]
Wireless keypad supervision failure
[6]
Wireless repeater supervision failure
[16]
Keypad fault (K32/K32+,K32RF only)
[
SLEEP
]
Keypad fault (K10V/H only)