22
Reference & Installation Manual
If the system is partitioned (see
Partitioning
on page 55), user codes with this option enabled can arm and disarm
partition 1.
If the system is not partitioned, you must assign partition 1 to the user access code. Otherwise, the
user access code will be considered disabled.
5.5.2
Partition 2 Assignment
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[2]
OFF = Deny access to partition 2 (default)
Option
[2]
ON
= User code has access to partition 2
If the system is partitioned (see
Partitioning
on page 55), user codes with this option enabled can arm and disarm
partition 2. If the system is not partitioned, the control panel ignores this option.
5.5.3
Bypass Programming
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[3]
OFF = Bypass Programming Disabled
Option
[3]
ON
= Bypass Programming Enabled (default)
User codes with this option enabled can perform Bypass Programming in assigned partitions.
5.5.4
Stay/Sleep Arming
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[4]
OFF = Stay/Sleep Arming Disabled
Option
[4]
ON
= Stay/Sleep Arming Enabled for selected User Code (default)
User codes with this option enabled can Stay or Sleep arm
assigned partitions.
5.5.5
Force Arming
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[5]
OFF = Force Arming Disabled
Option
[5]
ON
= Force Arming Enabled for selected User Code (default)
User codes with this option enabled can Force arm assigned partitions.
5.5.6
Arm Only
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[6]
OFF = Arm Only Disabled (default)
Option
[6]
ON
= Arm Only Enabled for selected User Code
The user code with this option enabled can arm assigned partitions, but cannot disarm any partitions. The type of
arming is dependent on the other User Code Options selected. Please note that with the Arm Only option, the user can
cancel a recently armed system by re-entering the access code before the end of the exit delay.
5.5.7
PGM Activation
Sections
[404]
to
[432]
: User Codes 004 to 048
Option
[7]
OFF = User Code follows User Code Options and can activate a PGM (default)
Option
[7]
ON
= User Code can activate a PGM only
With option
[7]
off, entering the access code will arm or disarm according to the programmed User Code Options as
well as activate or deactivate a PGM. The appropriate PGM Activation/Deactivation Event must also be programmed
(see
Programmable Outputs
on page 53). With option
[7]
on, the control panel will ignore all other User Code Options.
Therefore, entering the access code will only activate or deactivate the PGM.
5.5.8
Duress
Sections
[404]
to
[432]
: User Codes 004 to 032
Option
[8]
OFF = User Code with duress disabled (default)
Option
[8]
ON
= User Code with duress enabled
If you are coerced into arming or disarming your system, entering the access code with the duress option enabled will
arm or disarm the system and immediately transmit a silent alert (Duress Code) to the monitoring station.
5.6
Lock Master Code
Section
[701]
: System Options
Option
[2]
OFF = Lock System Master Code Disabled (default)
Option
[2]
ON = Lock System Master Code Enabled
With this feature enabled, the control panel will lock the System Master Code (001), it cannot be modified. With this feature
disabled, the control panel will unlock the System Master Code, so that it can be changed. The System Master Code cannot be
deleted (see Master Quick Menu Programming in the User Guide).