Magellan / Spectra SP
41
10.12 Auto-Arming Options
(Not to be used with UL installations)
Section
[741]
= Partition 1,
[742]
= Partition 2
When using Timed Auto-arming or No Movement Auto-arming, the control panel can Regular, Sleep or Stay arm the selected
partition.
10.13 One-Touch Arming
(Not to be used with UL installations)
Section
[703]
: Options
[1]
to
[3]
Option
[1]
ON = Press & hold the
[
ARM
]
key for One-touch Regular Arming.
Option
[2]
ON = Press & hold the
[
STAY
]
key for One-touch Stay Arming.
Option
[3]
ON = Press & hold the
[
SLEEP
]
key for One-touch Sleep Arming.
The One-touch arming features allow users to arm the system without having to enter any access codes. To arm the system,
press and hold the appropriate key (see above) for approximately 3 seconds. If the system is partitioned, you must also press the
key corresponding to the partition you wish to arm.
10.14 One-Touch Bypass Programming
(Not to be used with UL installations)
Section
[703]
: Options
[4]
Option
[4]
ON = Press & hold the
[
BYP
]
key for One-touch Bypass Programming.
Bypass programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the system is
armed. Press and hold the
[
BYP
]
key for three seconds to access bypass programming mode.
10.15 Exit Delay
Section
[745]
= Partition 1,
[746]
= Partition 2
001 to 255 seconds, Default = 60 seconds,
Maximum 60 seconds for UL Listed systems
After entering the required arming sequence (i.e. user access code, etc.), the exit delay parameter determines the amount of time
a user has to leave the protected area before the control panel arms the partition. The exit delay applies to all zones in the
selected partition. When enabled, the keypad will beep once every second during the exit delay and will beep rapidly during the
final 10 seconds of the exit delay.
10.15.1 Beep On Exit Delay
Section
[704]
: Arming/Disarming Options
Option
[6]
OFF = Beep on Exit Delay Disabled
Option
[6]
ON
= Beep on Exit Delay Enabled (default)
10.16 Bell Squawk On Arm/Disarm with Keypad
Section
[704]
: Arming/Disarming Options
Option
[5]
OFF = Bell Squawk on Arm/Disarm Disabled (default)
Option
[5]
ON = Bell Squawk on Arm/Disarm Enabled
When this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming via the keypad.
10.17 Bell Squawk On Arm/Disarm with Remote Control
Section
[704]
: Arming/Disarming Options
Option
[4]
OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default)
Option
[4]
ON = Bell Squawk on Arm/Disarm with Remote Control Enabled
When this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon disarming with
a remote control. Must be enabled for UL installations.
10.18 No Exit Delay When Arming with Remote Control
Section
[704]
: Arming/Disarming Options
Option
[8]
OFF = Provides Exit Delay When Arming with a Remote Control (default)
Option
[8]
ON = No Exit Delay When Arming with a Remote Control
When the option is enabled, the panel cancels the exit delay (arms instantly) when a partition is armed with a remote control.
When disabled, the exit delay timer will start when a partition is armed with a remote control.
[3]
[4]
OFF
OFF
Regular
OFF
ON
Sleep
ON
OFF
Stay