EVOHD User Manual
21
W
ARNING
:
For option
[2]
to function in the
ON
position, option
[5]
“Arm Only” in the User Options must be
disabled (refer to
).
Option [3]
: Card with Extended Unlocked Period
When option
[3]
is
ON
, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time
period programmed into each Access Control door by your installer that extends the unlocked time of the door.
For example, if your installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked
Period to 15 seconds, a user access code with “Extended Unlocked Period” enabled will have a total of 45
seconds to pass through the door.
Options [4] and [5]
: Arming with Card
Options
[4]
and
[5]
define the type of arming when arming with an Access Control card (refer to
).
You can either Regular arm, Stay arm, Force arm, or Disable the Arming with Card feature.
[4]
ON
,
[5]
OFF
= Regular Arm
[4]
OFF
,
[5]
ON
= Stay Arm
[4]
ON
,
[5]
ON
= Force Arm
[4]
OFF
,
[5]
OFF
= Disable the Arming with Card feature
Option [6]
: Add Tolerance Window to Schedule
When option
[6]
is
ON
, the Schedule Tolerance Window feature is enabled. This feature extends a user’s
scheduled access period through an Access Control door by the amount programmed by your installer. For
example, if the user’s assigned schedule for the door is Monday to Friday from 9:00 a.m. to 5:00 p.m., and your
installer sets the “Tolerance Window” at one hour, the user with the “Schedule Tolerance Window” enabled will
be able to enter and exit one hour before and after their scheduled time for that door.
Option [7]
: Code Follows Schedule
When option
[7]
is
ON
, users can use their access codes only during their scheduled hours assigned in step 8 in
. When the option is
OFF
, users can use their access codes at any time.
Option [8]
: Card to Unlock and Code to Disarm
Option
[8]
functions only if option
[2]
in section 7.7 is OFF. When option
[8]
is
ON
, a user can use an Access Control
card to unlock an armed Access Control door, however the user
must
enter a user access code to disarm the
armed area. When option
[8]
is
OFF
, a user can gain access to an Access Control door only if the door’s area(s) is
already disarmed.
W
ARNING
:
For option [8] to function in the ON position, option [
5
] “Arm Only” in the User Options must
be disabled (refer to
).