6 Installer’s Guide
2.0 INSTALLATION
2.1 L
OCATION
Mount the Liberator Wireless Bus Module on a wall allowing at least 5 cm (2")
around the module to permit adequate ventilation and heat dissipation. Select a site
that is not susceptible to drastic temperature changes. Avoid installation near or in
the path of strong RF fields (i.e. neon lights, computers), on or near metal objects,
circuit breaker boxes, air conditioners, and heater ducts since they may cause
interference and reduce its sensitivity. We recommend installing it in a centralized
location on the main floor. Avoid installing it in the basement. Refer to the
Digiplex
Control Panel's Reference & Installation Manual
for maximum allowable distances
between the control panel and the Liberator Wireless Bus Module.
2.2 C
ONNECTIONS
AND
M
OUNTING
Firmly screw the two antennae into the connectors marked "ANT" on the Receiver
Module (see Figure 2-1). Using a drill or screwdriver, punch out the four mounting
holes on the back of the plastic case. Align the six holes of the printed circuit board
with the six pins on the back plastic mounting case and snap into place. If placed
correctly, the antennae will lean directly over the grooves in the mounting case.
Do not cut, bend, or alter the antennae. Avoid mounting the Receiver
Module near or on metal as this may affect its sensitivity.
The Liberator Wireless Bus Module is connected to the control panel's DIGI-BUS in
a star and/or daisy chain configuration. The DIGI-BUS is a 4-wire communication
bus that provides power and two-way communication between the control panel and
all the modules connected to it. Connect the “
GRN
” and “
YEL
” terminals from the
Receiver Module to the corresponding “
GRN
” and “
YEL
” terminals of the control
panel. Connect the “
RED
” terminal to the “
AUX
+” of the control panel. Connect the
“
BLK
” terminal to the “
AUX
-” of the control panel.
Remove AC power and then remove the battery before adding a bus
module to the system or it may cause communication trouble.
I319EI01.fm Page 6 Wednesday, September 29, 1999 10:56 AM
Содержание Digiplex Liberator DGP-319
Страница 31: ...32 Installer s Guide 7 0 PGM PROGRAMMING TABLE I319EI01 fm Page 32 Wednesday September 29 1999 10 56 AM...
Страница 32: ...Digiplex Liberator 33 I319EI01 fm Page 33 Wednesday September 29 1999 10 56 AM...
Страница 33: ...34 Installer s Guide I319EI01 fm Page 34 Wednesday September 29 1999 10 56 AM...
Страница 34: ...Digiplex Liberator 35 I319EI01 fm Page 35 Wednesday September 29 1999 10 56 AM...
Страница 35: ...36 Installer s Guide I319EI01 fm Page 36 Wednesday September 29 1999 10 56 AM...
Страница 37: ...I319EI01 fm Page 38 Wednesday September 29 1999 10 56 AM...