15
*Ramp command not used with air conditioning
Refer to the table below for a list of the programming sections for all virtual inputs.
The following describes the programming sections and options specific to the Printer Module’s virtual inputs. Use the programming tables to
document specific settings for all programmed virtual inputs.
Each virtual input must be individually enabled. Set option
[1]
to ON to enable the virtual input.
U
= default setting
Each virtual input must be programmed to use a specific C-Bus application to monitor C-Bus activity. If option
[2]
is OFF,
lighting
application is used. If option
[2]
is ON,
air-conditioning
application is used.
U
= default setting
[702]
__/__/__ (000 to 255)
Virtual Input 1 Open
Group Address
Variable
000
[703]
__/__/__ (000 to 002)
Virtual Input 1 Open
Command
000*
[704]
__/__/__ (000 to 255)
Virtual Input 1 Close
Group Address
Variable
000
[705]
__/__/__ (000 to 002)
Virtual Input 1 Close
Command
000*
[706]
__/__/__ (000 to 255)
Ramp Threshold
000*
Virtual
Input
Section
Virtual
Input
Section
Virtual
Input
Section
Virtual
Input
Section
1
[700] - [706]
5
[740] - [746]
9
[780] - [786]
13
[820] - [826]
2
[710] - [716]
6
[750] - [756]
10
[790] - [796]
14
[830] - [836]
3
[720] - [726]
7
[760] - [766]
11
[800] - [806]
15
[840] - [846]
4
[730] - [736]
8
[770] - [776]
12
[810] - [816]
16
[850] - [856]
Section [700] - Option [1]
Enabling Virtual Input Option
Section
Virtual
Input
[1] OFF
[1] ON
Section
Virtual
Input
[1] OFF
[1] ON
[700]
1
U
disabled
N
enabled
[780]
9
U
disabled
N
enabled
[710]
2
U
disabled
N
enabled
[790]
10
U
disabled
N
enabled
[720]
3
U
disabled
N
enabled
[800]
11
U
disabled
N
enabled
[730]
4
U
disabled
N
enabled
[810]
12
U
disabled
N
enabled
[740]
5
U
disabled
N
enabled
[820]
13
U
disabled
N
enabled
[750]
6
U
disabled
N
enabled
[830]
14
U
disabled
N
enabled
[760]
7
U
disabled
N
enabled
[840]
15
U
disabled
N
enabled
[770]
8
U
disabled
N
enabled
[850]
16
U
disabled
N
enabled
Section [700] - Option [2]
C-Bus Application Selection
Section
Virtual
Input
[2] OFF
[2] ON
Section
Virtual
Input
[2] OFF
[2] ON
[700]
1
U
lighting
N
air-conditioning
[780]
9
U
lighting
N
air-conditioning
[710]
2
U
lighting
N
air-conditioning
[790]
10
U
lighting
N
air-conditioning
[720]
3
U
lighting
N
air-conditioning
[800]
11
U
lighting
N
air-conditioning
[730]
4
U
lighting
N
air-conditioning
[810]
12
U
lighting
N
air-conditioning
[740]
5
U
lighting
N
air-conditioning
[820]
13
U
lighting
N
air-conditioning
[750]
6
U
lighting
N
air-conditioning
[830]
14
U
lighting
N
air-conditioning
[760]
7
U
lighting
N
air-conditioning
[840]
15
U
lighting
N
air-conditioning
[770]
8
U
lighting
N
air-conditioning
[850]
16
U
lighting
N
air-conditioning