![Paradox Digiplex EVO PRT3 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/paradox/digiplex-evo-prt3/digiplex-evo-prt3_programming-instructions-manual_3599635010.webp)
9
*Not used with air-conditioning (values ignored if selected)
Refer to the table below for a list of the programming sections for all virtual PGMs.
The following describes the programming sections and options specific to the C-Bus entries. Use the programming tables to document
specific settings for all programmed C-Bus entries.
When option
[1]
is OFF, C-Bus entries are associated with
lighting
application. When option
[1]
is ON, C-Bus entries are associated with
air-conditioning
application.
U
= default setting
This option allows you to choose the type of command that will be sent through the C-Bus entry after the state of its associated virtual PGM
changes from OFF to ON. The types of commands include ON, OFF or ramp.
[404]
__/__/__ (000 to 255)
ON Ramp Final Level
000*
[405]
__/__/__ (000 to 255)
OFF Group Address
Variable
000
[406]
__/__/__ (000 to 015)
OFF Ramp Period
000*
[407]
__/__/__ (000 to 255)
OFF Ramp Final Level
000*
C-Bus Entry
Section
C-Bus Entry
Section
C-Bus Entry
Section
C-Bus Entry
Section
C-Bus Entry
Section
1
[400] - [407]
7
[460] - [467]
13
[520] - [527]
19
[580] - [587]
25
[640] - [647]
2
[410] - [417]
8
[470] - [477]
14
[530] - [537]
20
[590] - [597]
26
[650] - [657]
3
[420] - [427]
9
[480] - [487]
15
[540] - [547]
21
[600] - [607]
27
[660] - [667]
4
[430] - [437]
10
[490] - [497]
16
[550] - [557]
22
[610] - [617]
28
[670] - [677]
5
[440] - [447]
11
[500] - [507]
17
[560] - [567]
23
[620] - [627]
29
[680] - [687]
6
[450] - [457]
12
[510] - [517]
18
[570] - [577]
24
[630] - [637]
30
[690] - [697]
Section [400] - Option [1]
Application Selection
Section
C-Bus
Entry
[1] OFF
[1] ON
Section
C-Bus Entry
[1] OFF
[1] ON
[400]
1
U
lighting
N
air-conditioning
[550]
16
U
lighting
N
air-conditioning
[410]
2
U
lighting
N
air-conditioning
[560]
17
U
lighting
N
air-conditioning
[420]
3
U
lighting
N
air-conditioning
[570]
18
U
lighting
N
air-conditioning
[430]
4
U
lighting
N
air-conditioning
[580]
19
U
lighting
N
air-conditioning
[440]
5
U
lighting
N
air-conditioning
[590]
20
U
lighting
N
air-conditioning
[450]
6
U
lighting
N
air-conditioning
[600]
21
U
lighting
N
air-conditioning
[460]
7
U
lighting
N
air-conditioning
[610]
22
U
lighting
N
air-conditioning
[470]
8
U
lighting
N
air-conditioning
[620]
23
U
lighting
N
air-conditioning
[480]
9
U
lighting
N
air-conditioning
[630]
24
U
lighting
N
air-conditioning
[490]
10
U
lighting
N
air-conditioning
[640]
25
U
lighting
N
air-conditioning
[500]
11
U
lighting
N
air-conditioning
[650]
26
U
lighting
N
air-conditioning
[510]
12
U
lighting
N
air-conditioning
[660]
27
U
lighting
N
air-conditioning
[520]
13
U
lighting
N
air-conditioning
[670]
28
U
lighting
N
air-conditioning
[530]
14
U
lighting
N
air-conditioning
[680]
29
U
lighting
N
air-conditioning
[540]
15
U
lighting
N
air-conditioning
[690]
30
U
lighting
N
air-conditioning
Section [400] - Options [2] and [3]
ON Commands