14
The OFF Ramp Final Level section allows you to assign a final level of light intensity when an OFF Ramp command has been set (see “OFF
Commands” on page 10). Enter
000
-
255
to assign each C-Bus entry an OFF Ramp Final Level.
For further information on lighting intensity levels associated with the OFF Ramp command, refer to the appropriate C-Bus
documentation.
Virtual Input Options
The Printer Module features 16 virtual inputs. The virtual inputs’ open/close state can change based on an event that has occurred within
C-Bus. The following describes the programming sections and options specific to the Printer Module’s virtual inputs. Virtual inputs must be
programmed with the appropriate C-Bus application, group address variable and type of command which will cause the virtual input to
react (open/close).
The tables below offer an example of the virtual input programming sections which must be set for virtual input 1.
[526]
13
[676]
28
[536]
14
[686]
29
[546]
15
[696]
30
Section [407]*
OFF Ramp Final Level
* Not used with air conditioning
Section
C-Bus Entry
OFF Ramp Final
Level
Section
C-Bus Entry
OFF Ramp Final
Level
[407]
1
[557]
16
[417]
2
[567]
17
[427]
3
[577]
18
[437]
4
[587]
19
[447]
5
[597]
20
[457]
6
[607]
21
[467]
7
[617]
22
[477]
8
[627]
23
[487]
9
[637]
24
[497]
10
[647]
25
[507]
11
[657]
26
[517]
12
[667]
27
[527]
13
[677]
28
[537]
14
[687]
29
[547]
15
[697]
30
Section [700] : Virtual Input Options
Option
OFF
ON
[1]
Enabling Virtual Input
U
Disabled
N
Enabled
[2]
C-Bus Application Selection
U
Lighting
N
Air-conditioning
[3] and [4]
Virtual Input Close
[5]
Virtual Input Base Time
Selection
U
Seconds
N
Minutes
Section
Data
Description
Default
[701]
__/__/__ (000 to 255) x Base Time
Virtual Input 1 Timer
005