 Reference & Installation Manual

2.0 Installation

2.1 Connecting the Keypad

The DGP2-640 is connected to the control panel’s combus in a star 
and/or daisy chain configuration. The four-wire combus provides 
power and two-way communication between the control panel and all 
modules connected to it. Connect the four terminals labeled 

+

-

GRN

 

and 

YEL

 on the keypad to the corresponding terminals on the control 

panel as shown in Figure 1 on page 3. Refer to the control panel’s

 

Reference & Installation Manual

 for the maximum allowable 

installation distance from the control panel.

2.2 Connecting the Keypad Zone

Your keypad has one hardwired input terminal, allowing you to 
connect one detector or door contact directly to it. For example, you 
can wire a door contact located at the entry point of an establishment 
directly to the input terminal of the entry point keypad, instead of 
wiring the door contact all the way to the control panel.

Connect the device to the keypad's input terminal as shown in Figure 
1 on page 3.

The keypad zone follows the control panel’s EOL definition.

In order to communicate its status to the control panel, the keypad's 
input must be assigned to a zone in the control panel and the zone's 
parameters must be defined.

The control panel does not recognize tampers originating 
from the keypad zone.

For more information on zone assignment, please refer to your 
control panel's

 Reference & Installation Manual

. Please note that 

even with the ATZ (zone doubling) feature enabled, the keypad 

DGP2640_EI00.fm  Page 2  Thursday, April 7, 2005  12:05 PM

Содержание Digiplex EVO DGP2-640

Страница 1: ...Icon LCD Keypad V1 0 Reference Installation Manual DGP2 640...

Страница 2: ......

Страница 3: ...mming Mode 4 Programming Methods 5 Module Broadcast 5 System Options 7 Partition Display 7 Confidential Mode 8 Exit Confidential Mode 8 Muting 8 Beep on Exit Delay 9 Chime on Zone Closure 9 Time Forma...

Страница 4: ...PGM Activation 12 PGM Deactivation 13 PGM Test 13 List of Sections 14...

Страница 5: ...r input 12 16 Vdc 80mA maximum PGM current limit 50mA Number of inputs 1 Number of zones 1 standard zone no tamper recognition Locate deactivation Anti tamper switch Compatibility Any Digiplex control...

Страница 6: ...llowing you to connect one detector or door contact directly to it For example you can wire a door contact located at the entry point of an establishment directly to the input terminal of the entry po...

Страница 7: ...xceed the current limit a relay should be connected to the PGM as shown in Figure 1 Figure 1 Connecting Keypads and Keypad Zones A keypad s input must be assigned to a zone keyswitch or virtual input...

Страница 8: ...ud with a 306 Adapter For more information refer to the WinLoad instructions or visit our website at www paradox ca 3 1 Entering Module Programming Mode The keypad like all other modules in the system...

Страница 9: ...again to remove the digit from the display thereby disabling the option Press the key when options are set 3 2 2 Decimal Programming Some sections require that a decimal value be entered In this meth...

Страница 10: ...ce s data If you want to program more than one keypad with the source s data enter the serial numbers of the keypads one at a time 6 Once you have entered the serial numbers of the keypad s you want t...

Страница 11: ...04 which represents LCD numbers 1 to 4 respectively Do not assign the same display number to more than one section For example you cannot assign value 002 to sections 003 and 004 The rejection beep wi...

Страница 12: ...Exit Confidential Mode Section 009 Option 2 If confidential mode is enabled option 2 determines how the keypad will return to normal mode after the keypad has switched to confidential mode see Confide...

Страница 13: ...ver a zone with the Chime feature enabled closes see the DGP2 640 User Guide for details on Chime Zones If the user does not set the Chime Zone time period and this option is enabled the Chime Zones w...

Страница 14: ...Troubles Option 2 OFF Disabled default Option 2 ON Enabled Module Combus Troubles Option 3 OFF Disabled default Option 3 ON Enabled Zone Troubles Option 4 OFF Disabled default Option 4 ON Enabled 4 9...

Страница 15: ...he ground and enable any devices connected to it When a closed PGM is activated it will open the circuit and disable any devices connected to it When the PGM Activation Event occurs see PGM Activation...

Страница 16: ...ied by the PGM Base Time of 1 second or 1 minute see PGM Base Time on page 12 5 5 PGM Activation Sections 014 to 017 Modules belonging to the DGP2 series are programmed using the PGM Programming table...

Страница 17: ...the event the Feature Group identifies the source and the Start and End set the range within the Feature Group Use the PGM Programming Table in the Digiplex Modules Programming Guide to program the k...

Страница 18: ...ction A maximum of 4 partitions can be assigned to the keypad Section Description Data Default 001 Partition 1 Display __ __ __ 000 to 004 001 002 Partition 2 Display __ __ __ 000 to 004 002 003 Parti...

Страница 19: ...4 Beep on Exit Delay N Disabled U Enabled 5 Chime on Zone Closure U Disabled N Enabled 6 Time Format U International N U S a m p m Section 010 Beep on Trouble Option Description OFF ON 1 Beep on Syst...

Страница 20: ...Tamper U Disabled N Enabled Section Data Description Default 012 __ __ __ 005 255 Confidential Mode Timer 120s Section Data Description Default 013 __ __ __ 001 255 PGM Timer 005 Event group Feature...

Страница 21: ...ether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arisi...

Страница 22: ......

Страница 23: ......

Страница 24: ...to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox ca 780 Indus...

Отзывы: