DGP2-640 Icon LCD Keypad
11
4.10 Confidential Mode Timer
Section
[012]
: Default = 120 seconds
Section
[012]
determines the amount of time a keypad is inactive
before the keypad enters Confidential Mode. For more information,
refer to
Confidential Mode
on page 8. The Confidential Mode timer
can be set from 005 seconds to 255 seconds.
5.0 Programmable Output Options
5.1 PGM State
Section
[011]
: Option
[1]
The keypad's on-board PGM can be set as normally open or
normally closed. When an open PGM is activated, it will close the
circuit to the ground and enable any devices connected to it. When a
closed PGM is activated, it will open the circuit and disable any
devices connected to it. When the PGM Activation Event occurs (see
PGM Activation
on page 12), the PGM will switch to its opposite state
(i.e. open to closed or closed to open). The PGM is limited to 50mA.
Option
[1]
OFF = PGM is Normally Open (default)
Option
[1]
ON = PGM is Normally Closed
5.2 PGM Deactivation Mode
Section
[011]
: Option
[2]
If option
[2]
is enabled, the keypad's on-board PGM will be
deactivated according to the PGM Timer
(see
PGM Timer
on page
12) instead of the PGM Deactivation Event.
Option
[2]
OFF = Deactivation follows PGM Deactivation Event (default)
Option
[2]
ON = PGM will deactivate according to the PGM Timer
DGP2640_EI00.fm Page 11 Thursday, April 7, 2005 12:05 PM