background image

DGP2-640 Icon LCD Keypad  

13

5.6 PGM Deactivation 

Sections 

[018]

 to 

[021]

Modules belonging to the DGP2 series are programmed using the 
PGM Programming table in the 

Digiplex Modules’ Programming 

Guide

. If the PGM Deactivation Option is set to follow the PGM 

Deactivation Event, the PGM will return to its normal state when the 
event programmed in sections 

[018]

 to 

[021]

 occurs. The Event 

Group specifies the event, the Feature Group identifies the source 
and the Start # and End # set the range within the Feature Group. 
Use the PGM Programming Table in the 

Digiplex Modules’ 

Programming Guide

 to program the keypad’s PGM Deactivation 

Event.

Enter the sections that correspond to the Event Group, Feature 
Group, Start # and End # of the PGM and enter the required data.

5.7 PGM Test

Section 

[030] 

 

Use this section to initiate a PGM test, which will activate the PGM 
for 8 seconds. Enter section

 [030] 

to activate this test.

Event Group

Feature Group Start #

End #

PGM [018] __/__/__ [019]__/__/__

[020]__/__/__ [021]__/__/__

DGP2640_EI00.fm  Page 13  Thursday, April 7, 2005  12:05 PM

Содержание Digiplex EVO DGP2-640

Страница 1: ...Icon LCD Keypad V1 0 Reference Installation Manual DGP2 640...

Страница 2: ......

Страница 3: ...mming Mode 4 Programming Methods 5 Module Broadcast 5 System Options 7 Partition Display 7 Confidential Mode 8 Exit Confidential Mode 8 Muting 8 Beep on Exit Delay 9 Chime on Zone Closure 9 Time Forma...

Страница 4: ...PGM Activation 12 PGM Deactivation 13 PGM Test 13 List of Sections 14...

Страница 5: ...r input 12 16 Vdc 80mA maximum PGM current limit 50mA Number of inputs 1 Number of zones 1 standard zone no tamper recognition Locate deactivation Anti tamper switch Compatibility Any Digiplex control...

Страница 6: ...llowing you to connect one detector or door contact directly to it For example you can wire a door contact located at the entry point of an establishment directly to the input terminal of the entry po...

Страница 7: ...xceed the current limit a relay should be connected to the PGM as shown in Figure 1 Figure 1 Connecting Keypads and Keypad Zones A keypad s input must be assigned to a zone keyswitch or virtual input...

Страница 8: ...ud with a 306 Adapter For more information refer to the WinLoad instructions or visit our website at www paradox ca 3 1 Entering Module Programming Mode The keypad like all other modules in the system...

Страница 9: ...again to remove the digit from the display thereby disabling the option Press the key when options are set 3 2 2 Decimal Programming Some sections require that a decimal value be entered In this meth...

Страница 10: ...ce s data If you want to program more than one keypad with the source s data enter the serial numbers of the keypads one at a time 6 Once you have entered the serial numbers of the keypad s you want t...

Страница 11: ...04 which represents LCD numbers 1 to 4 respectively Do not assign the same display number to more than one section For example you cannot assign value 002 to sections 003 and 004 The rejection beep wi...

Страница 12: ...Exit Confidential Mode Section 009 Option 2 If confidential mode is enabled option 2 determines how the keypad will return to normal mode after the keypad has switched to confidential mode see Confide...

Страница 13: ...ver a zone with the Chime feature enabled closes see the DGP2 640 User Guide for details on Chime Zones If the user does not set the Chime Zone time period and this option is enabled the Chime Zones w...

Страница 14: ...Troubles Option 2 OFF Disabled default Option 2 ON Enabled Module Combus Troubles Option 3 OFF Disabled default Option 3 ON Enabled Zone Troubles Option 4 OFF Disabled default Option 4 ON Enabled 4 9...

Страница 15: ...he ground and enable any devices connected to it When a closed PGM is activated it will open the circuit and disable any devices connected to it When the PGM Activation Event occurs see PGM Activation...

Страница 16: ...ied by the PGM Base Time of 1 second or 1 minute see PGM Base Time on page 12 5 5 PGM Activation Sections 014 to 017 Modules belonging to the DGP2 series are programmed using the PGM Programming table...

Страница 17: ...the event the Feature Group identifies the source and the Start and End set the range within the Feature Group Use the PGM Programming Table in the Digiplex Modules Programming Guide to program the k...

Страница 18: ...ction A maximum of 4 partitions can be assigned to the keypad Section Description Data Default 001 Partition 1 Display __ __ __ 000 to 004 001 002 Partition 2 Display __ __ __ 000 to 004 002 003 Parti...

Страница 19: ...4 Beep on Exit Delay N Disabled U Enabled 5 Chime on Zone Closure U Disabled N Enabled 6 Time Format U International N U S a m p m Section 010 Beep on Trouble Option Description OFF ON 1 Beep on Syst...

Страница 20: ...Tamper U Disabled N Enabled Section Data Description Default 012 __ __ __ 005 255 Confidential Mode Timer 120s Section Data Description Default 013 __ __ __ 001 255 PGM Timer 005 Event group Feature...

Страница 21: ...ether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arisi...

Страница 22: ......

Страница 23: ......

Страница 24: ...to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox ca 780 Indus...

Отзывы: