16
Reference & Installation Manual
U
= Default
PGM Activation
PGM Deactivation
Section [011]: PGM & Keypad Tamper Options
Option
Description
OFF
ON
[1]
PGM State
U
N.O.
N
N.C.
[2]
PGM Deactivation
Mode
U
Deactivation
Event
N
PGM Timer
[3]
PGM Base Time
U
Seconds
N
Minutes
[5]
Keypad Anti-Tamper
U
Disabled
N
Enabled
Section
Data
Description
Default
[012]
__/__/__ (005-255) Confidential Mode Timer 120s
Section
Data
Description
Default
[013]
__/__/__ (001-255) PGM Timer
005
Event group
Feature group Start #
End #
PGM [014] __/__/__ [015]__/__/__
[016]__/__/__ [017]__/__/__
Event group
Feature group Start #
End #
PGM [018] __/__/__ [019]__/__/__
[020]__/__/__ [021]__/__/__
Section
Description
[030]
Test PGM: Activate PGM for 8 seconds to verify if the
PGM is functioning properly