background image

 

DGP-NE96 Control Panel

 15

5.2.4 Generates a Utility Key Event on Open

S

ECTIONS

 [0601] 

TO

 [0632]: F

IRST

 

DIGIT

 = 3

When option 

[3]

 is enabled, a Utility Key Event will be generated whenever 

the keyswitch input is opened (see Table 14 on page 49). This option can 
be used to activate or deactivate one or more of DGP-NE96’s PGM 
outputs. When a keyswitch is defined with the Generate a Utility Key Event 
on Open option, the Keyswitch Partition Assignment and Keyswitch 
Options are disabled. To program a keyswitch to generate a Utility Key 
Event:

1. Program the Activation Event of a PGM output with the 

Utility Key

 

Event corresponding to the desired keyswitch (see 

PGM 

Programming Table

 in the Programming Guide: Event Group 048). 

2. Enable option [3] in the section corresponding to the desired 

keyswitch.

5.2.5 Generates a Utility Key Event on Open and Close

S

ECTIONS

 [0601] 

TO

 [0632]: F

IRST

 

DIGIT

 = 4

When option 

[4]

 is enabled, a Utility Key Event will be generated whenever 

the keyswitch input is opened or closed. As a result, the Utility Key Events 
increase from 32 to 64 events when option 

[4]

 is enabled; one event for 

each state (open and closed). See Table 14 on page 49

This option can be used to activate or deactivate one or more of DGP-
NE96’s PGM outputs. When a keyswitch is defined with the Generate a 
Utility Key Event on Open and Close option, the Keyswitch Partition 
Assignment and Keyswitch Options are disabled. To program a keyswitch 
to generate a Utility Key Event:

1. Program the Activation Event of a PGM output with the 

Utility Key

 

Event corresponding to the desired keyswitch (see 

PGM 

Programming Table

 in the Programming Guide: Event Group 048). 

2. Enable option 

[4]

 in the section corresponding to the desired 

keyswitch.

5.3 Keyswitch Partition Assignment

S

ECTIONS

 [0601] 

TO

 [0632]: S

ECOND

 

DIGIT

 = 1 

TO

 8

The control panel provides the option of partitioning the security system into 
eight completely independent systems. Therefore, each keyswitch must be 
assigned to one partition as shown in Figure 17 on page 14. For details on 
Partitioning, see section 11.9 on page 31. 

5.4 Keyswitch Options

Each keyswitch zone can be programmed with one or more of the options 
below as shown in Figure 17 on page 14.

5.4.1 Stay/Instant Disarm Option (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [4] 

When option 

[4]

 is enabled, the keyswitch can only disarm assigned Stay or 

Instant armed partitions. The Arm Only Option (see section 5.4.2) must be 
disabled for this feature to function. When option 

[4]

 is disabled, the 

keyswitch can disarm partitions armed using any arming method.

5.4.2 Arm Only (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [5] 

When option 

[5]

 is enabled, the keyswitch can arm assigned partitions, but 

cannot disarm any partitions. The type of arming is determined by the other 
Keyswitch Options selected.

5.4.3 Regular Arming (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [6] 

TO

 [8]

When options 

[6]

 to 

[8]

 are disabled, the keyswitch arming option will 

default to Regular arming (see section 15.1 on page 40). 

5.4.4 Stay Arming (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [6]

Activating the keyswitch will bypass any zones defined as Stay Zones (see 
section 4.5.3 on page 13)
 in the selected partition. All other zones will 
remain activated. For more information on Stay arming, refer to section 
15.2 on page 40.

5.4.5 Force Arming (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [7]

Activating the keyswitch will arm the selected partition bypassing any open 
zones defined as Force Zones (see section 4.5.4 on page 13) at the time of 
arming. For more information on Force arming, refer to section 15.4 on 
page 40.

5.4.6 Instant Arming (Keyswitch)

S

ECTIONS

 [0601] 

TO

 [0632]: O

PTION

 [8]

This option is identical to Stay arming except that all armed zones will 
become Instant Zones (see section 4.3.4 on page 11). For more information 
on Instant arming, refer to section 15.3 on page 40.

Only one of the arming options (Stay, Force, Instant and Regular) 
can be selected.

Содержание DIGIPLEX DGP-NE96

Страница 1: ...V1 5 96 Zone Expandable Security and Access Control Panel DGP NE96 Reference and Installation Manual DGP NE96 www paradox ca...

Страница 2: ......

Страница 3: ...e 16 Restrict Arming on Module Troubles 16 Timed Auto Arming 16 No Movement Auto Arming 17 Auto Arming Options 17 Switch To Stay Arming 17 Always Force Arm when Regular Arming 17 Follow Zone Switches...

Страница 4: ...evels 36 Access Schedules 36 Backup Schedules 37 Holiday Programming 37 Schedule Tolerance Window 37 Door Access Mode 37 Code Access 37 Card and Code Access 37 Skip Exit Delay When Arming With Access...

Страница 5: ...the CTR 21 approval are available as an option only 1 1 Features Digital combus Provides constant power supervision and two way communication between the control panel and all its modules Supports up...

Страница 6: ...a 12Vdc 4Ah rechargeable acid lead or gel cell backup battery YUASA model NP7 12 recommended as shown in Figure 3 on page 3 Connect the backup battery after applying AC power When installing verify pr...

Страница 7: ...resistor as close as possible to the bell A resistor is not required for sirens The bell output will shut down if the current exceeds 3A Bell Siren 1K9 resistor Bell Siren 1K9 resistor Transformer Re...

Страница 8: ...ion Module DGP2 ZX1 _______ X 14PU __________ PU 4 Zone Hardwire Module APR3 ZX4 _______ X 28PU __________ PU 8 Zone Hardwire Module APR3 ZX8 _______ X 28PU __________ PU Wireless Module OMN RCV3 ____...

Страница 9: ...rdwired input terminals for use with traditional hardwired non combus door contacts smoke detectors and or motion detectors The control panel also supports several hardwire zone expansion modules Devi...

Страница 10: ...nsion Plug in Device DGP2 ZX4 provides four additional hardwired input terminals 8 zones with ATZ enabled It connects directly to the control panel through its on board EXPANSION connector as shown in...

Страница 11: ...ote Not to be used with UL Listed systems 2 17 2 ESL CleanMe Installation The DGP NE96 control panel supports ESL smoke detectors that have the CleanMe feature Connect ESL smoke detectors like the sta...

Страница 12: ...ored in the RTC every hour If the times are different the DGP NE96 will reset its internal clock to the time saved in the RTC The RTC uses a 3V lithium battery CR2032 with a battery life of 11 years C...

Страница 13: ...he next section Press the right action key Exit to revert to the preceding step or press the left action key Clear to erase the current data 3 4 1 Feature Select Programming Most of the options are pr...

Страница 14: ...d to it Enter the module s 3 digit INPUT NUMBER where the hardwire device is connected NOTE For addressable PIRs door contacts and keypads no input is required Zone Definition First Digit Zone Partiti...

Страница 15: ...ters through the entry point to disarm the system 4 3 4 Instant Zones SECTIONS 0101 TO 0196 FIRST DIGIT 4 When an armed Instant zone opens the control panel immediately generates an alarm Instant zone...

Страница 16: ...ction 4 3 4 on page 11 When a Stay Delay zone is armed using the Stay or Instant arming methods and the zone is triggered the control panel will not generate an alarm until the programmed Stay Delay e...

Страница 17: ...e into effect until the Input Speed elapses The control panel will not display and or respond to an open zone until the Input Speed elapses to prevent glitches from causing an alarm or unnecessary rep...

Страница 18: ...tion using the Maintained Keyswitch turn the switch from the ON to the OFF position To disarm a partition set the keyswitch in the ON position The selected Keyswitch Option see section 5 4 on page 15...

Страница 19: ...ing the security system into eight completely independent systems Therefore each keyswitch must be assigned to one partition as shown in Figure 17 on page 14 For details on Partitioning see section 11...

Страница 20: ...le if options 1 2 and 5 are ON in section 3035 the control panel prevents arming if it detects an AC or battery failure on the control panel or on a module connected to the combus 6 9 Timed Auto Armin...

Отзывы: