DGP-NE96 Control Panel

 1

1  

Introduction

The Digiplex DGP-NE96 is a security and access control system with 8 on-
board zone inputs (16 with zone doubling) that is expandable to 96 zones 
via the 4-wire combus. The DGP-NE96 control panel features up to 999 
users, 8 partitions, 32 doors, 32 schedules, 16 access levels, and can 
support up to 127 modules in any combination.

The Digiplex DGP-NE96 system provides the highest level of protection for 
banks, high-security military and government sites, luxurious residential 
homes and any place where maximum security is essential. These systems 
are designed to be easy to use, and the modular concept of these systems 
provides installers with labour-saving features that make expanding, 
installing and servicing these systems quick and convenient.

Expand the DGP-NE96 system by adding plug-and-play expansion 
modules anywhere and in any combination on the 4-wire combus. Modules 
are connected to the combus at the most convenient location and then their 
zone inputs are assigned to the desired zone and partition. Also, only a 
module’s used inputs are assigned to zones in the system. Keyswitches, 
remote controls and unused module inputs do not use up zones. Once 
installed, all combus modules, including motion detectors, can be 
programmed remotely via a keypad or the WinLoad upload/download 
software.

DGP-NE96 also supports 32 virtual zones in addition to its 96 security 
zones and 32 access control doors. Virtual zones can be used to automate 
PGM activations without occupying a security zone and without affecting 
the system’s security functions. The DGP-NE96 system is a logical solution 
to every installer’s security, access control and home automation 
installation needs.

CTR-21 APPROVAL 

The DGP-NE96 control panel meets the European Union Common 
Technical Requirement CTR-21. The CTR-21 requirement is an electrical 
standard that defines the analogue interface for all two-wire 
telecommunications equipment (i.e. DECT, PABXs, etc.) intended for 
connection to the Public Switched Telephone Network. This allows the 
DGP-NE96 control panel to be used in as many as 19 countries, such as 
Belgium, Germany, Greece, Portugal, Sweden and Switzerland. 
DGP-NE96 control panels with the CTR-21 approval are available as an 
option only. 

1.1 Features

‹

Digital combus:

Provides constant power, supervision and two-way communication 
between the control panel and all its modules 

Supports up to 127 modules 

Connect modules up to 914m (3000ft) from the panel

Sabotage-proof technology without additional wiring

‹

96 addressable zones

‹

8 partitions

‹

998 user codes, 1 System Master code and 1 Installer code

‹

Built-in access control 

‹

2048 stored events

‹

1 telephone line and optional secondary telephone line

‹

Remote diagnostics and pager messaging

‹

False alarm prevention features

‹

32 independent keyswitch zones (does not use any of the 96 zones)

‹

8 on-board hardwired input terminals 

‹

3 on-board fully programmable outputs (PGMs):

1 normally open, high-current transistor output (100mA)

2 normally open or normally closed 5A programmable relay outputs

Up to 32 more PGM inputs through the keyswitch’s PGM Input 
feature

‹

PGM1 can be set as a two-wire smoke detector input

‹

Event reporting:

a separate dialing sequence for each partition

4 Monitoring Station Telephone Numbers 

SIA, Contact ID, Ademco Contact ID Edition 2000, Pager Format 
and many more communicator formats

1.2 Specifications

Control Panel (Non-UL systems)

AC Power:

16Vac, 20/40VA, 50-60Hz

Battery:

12Vdc, 4Ah minimum

Auxiliary Power:

12Vdc 600mA typical, 700mA maximum, 
fuseless shutdown at 1.1A

Bell Output:

1A, fuseless shutdown @ 3A

PGM Output:

PGM1 (100mA), PGM2 and PGM3 (5A relay)

Event Buffer:

2048 events

All control panel outputs are rated to operate between 10.8Vdc and 
12.1Vdc

Control Panel (UL compliant systems)

AC Power:

16Vac, 40VA, 60Hz

Battery:

12Vdc, 4Ah minimum

Auxiliary Power:

11.4 to 12.5Vdc, 200mA maximum, fuseless 
shutdown at 1.1A

Bell Output:

11.4 to 12.5Vdc, 1A maximum, fuseless 
shutdown @ 3A

PGM Output:

PGM1 (100mA), PGM2 and PGM3 (5A relay)

Event Buffer:

2048 events

All control panel outputs are rated to operate between 11.4Vdc and 
12.5Vdc

Specifications may change without prior notice.

UL Note:

 The DGP-NE96 control panel has been tested with the LCD Keypad 

(DGP2-641) only.

General Note 1

Please note that only LCD and Grafica keypads can be used to program the 
DGP-NE96. LED keypads cannot be used to program the system.

General Note 2

Please note that the steps may differ when programming with the Grafica 
keypad (DNE-K07). If not indicated, refer to the complete Grafica User 
Manual, which can be downloaded for free from our website at 
www.paradox.ca.

Содержание DIGIPLEX DGP-NE96

Страница 1: ...V1 5 96 Zone Expandable Security and Access Control Panel DGP NE96 Reference and Installation Manual DGP NE96 www paradox ca...

Страница 2: ......

Страница 3: ...e 16 Restrict Arming on Module Troubles 16 Timed Auto Arming 16 No Movement Auto Arming 17 Auto Arming Options 17 Switch To Stay Arming 17 Always Force Arm when Regular Arming 17 Follow Zone Switches...

Страница 4: ...evels 36 Access Schedules 36 Backup Schedules 37 Holiday Programming 37 Schedule Tolerance Window 37 Door Access Mode 37 Code Access 37 Card and Code Access 37 Skip Exit Delay When Arming With Access...

Страница 5: ...the CTR 21 approval are available as an option only 1 1 Features Digital combus Provides constant power supervision and two way communication between the control panel and all its modules Supports up...

Страница 6: ...a 12Vdc 4Ah rechargeable acid lead or gel cell backup battery YUASA model NP7 12 recommended as shown in Figure 3 on page 3 Connect the backup battery after applying AC power When installing verify pr...

Страница 7: ...resistor as close as possible to the bell A resistor is not required for sirens The bell output will shut down if the current exceeds 3A Bell Siren 1K9 resistor Bell Siren 1K9 resistor Transformer Re...

Страница 8: ...ion Module DGP2 ZX1 _______ X 14PU __________ PU 4 Zone Hardwire Module APR3 ZX4 _______ X 28PU __________ PU 8 Zone Hardwire Module APR3 ZX8 _______ X 28PU __________ PU Wireless Module OMN RCV3 ____...

Страница 9: ...rdwired input terminals for use with traditional hardwired non combus door contacts smoke detectors and or motion detectors The control panel also supports several hardwire zone expansion modules Devi...

Страница 10: ...nsion Plug in Device DGP2 ZX4 provides four additional hardwired input terminals 8 zones with ATZ enabled It connects directly to the control panel through its on board EXPANSION connector as shown in...

Страница 11: ...ote Not to be used with UL Listed systems 2 17 2 ESL CleanMe Installation The DGP NE96 control panel supports ESL smoke detectors that have the CleanMe feature Connect ESL smoke detectors like the sta...

Страница 12: ...ored in the RTC every hour If the times are different the DGP NE96 will reset its internal clock to the time saved in the RTC The RTC uses a 3V lithium battery CR2032 with a battery life of 11 years C...

Страница 13: ...he next section Press the right action key Exit to revert to the preceding step or press the left action key Clear to erase the current data 3 4 1 Feature Select Programming Most of the options are pr...

Страница 14: ...d to it Enter the module s 3 digit INPUT NUMBER where the hardwire device is connected NOTE For addressable PIRs door contacts and keypads no input is required Zone Definition First Digit Zone Partiti...

Страница 15: ...ters through the entry point to disarm the system 4 3 4 Instant Zones SECTIONS 0101 TO 0196 FIRST DIGIT 4 When an armed Instant zone opens the control panel immediately generates an alarm Instant zone...

Страница 16: ...ction 4 3 4 on page 11 When a Stay Delay zone is armed using the Stay or Instant arming methods and the zone is triggered the control panel will not generate an alarm until the programmed Stay Delay e...

Страница 17: ...e into effect until the Input Speed elapses The control panel will not display and or respond to an open zone until the Input Speed elapses to prevent glitches from causing an alarm or unnecessary rep...

Страница 18: ...tion using the Maintained Keyswitch turn the switch from the ON to the OFF position To disarm a partition set the keyswitch in the ON position The selected Keyswitch Option see section 5 4 on page 15...

Страница 19: ...ing the security system into eight completely independent systems Therefore each keyswitch must be assigned to one partition as shown in Figure 17 on page 14 For details on Partitioning see section 11...

Страница 20: ...le if options 1 2 and 5 are ON in section 3035 the control panel prevents arming if it detects an AC or battery failure on the control panel or on a module connected to the combus 6 9 Timed Auto Armin...

Отзывы: