Reference & Installation Manual

4  

Zone Programming

All detection devices connected to the control panel, keypads and zone expansion modules must be assigned to a zone and that zone must be defined as 
described in this section. 

Figure 13: Zone Programming

4.1 Zone Numbering

S

ECTIONS

 [0001] 

TO

 [0096]

The Zone Numbering feature is used to individually assign each detection 
device to any zone in the DGP-NE96 system (see Figure 13). The Zone 
Parameters define the type of zone, the zone's partition assignment and 
how the control panel will react when an alarm occurs on that zone (see 
section 4.3 to section 4.5 on pages 11 to 13)
• To assign an addressable PIR or door contact to the combus, program 

the module’s serial number into the section corresponding to the desired 
zone (i.e. program zone 34 in section [0034]). 

• To assign a detection device connected to a module or control panel's 

hardwired input terminal, program the module's or control panel's serial 
number and the input number where the device is connected into the 
section corresponding to the desired zone. See the 

Module 

Programming Guide

 for details of its input numbers (input numbers not 

required for keypad zones).

If PGM1 is defined as a smoke detector input (see section 10.6 
on page 29), the co
ntrol panel will recognize it as input # 255.

Figure 14:  Zone Numbering

Press & hold the

[0]

 key

Key in the 

[

INSTALLER

 

CODE

]

Key in 4-digit

[

SECTION

]

Enter the 8-digit 

[

SERIAL

 

NUMBER

] of the 

addressable detection device or 

module that has a hardwire 

device connected to it.

Enter the module’s 3-digit 
[

INPUT

 

NUMBER

] where the 

hardwire device is connected.

NOTE: For addressable PIRs, door 
contacts and keypads, no input # is 

required

Zone Definition

First Digit

Zone Partition 

Assignment

Second Digit

Zone Options

Feature Select

Press 

[

ENTER

]

Zone Options

[1] Auto Zone Shutdown

[2] Bypass Zone (Default)

[3] Stay Zone
[4] Force Zone
[5]

[6]

Zone Alarm Type

off

off

Alarm (steady)

off

on

Audible Alarm (pulsed)

on

off

Silent Alarm

on

on

Generates only a report

[7] Intellizone
[8] Delay before transmission

Zone Partition Assignment

1- Zone Assigned to Partition 1 (Default)

2- Zone Assigned to Partition 2
3- Zone Assigned to Partition 3
4- Zone Assigned to Partition 4
5- Zone Assigned to Partition 5
6- Zone Assigned to Partition 6
7- Zone Assigned to Partition 7
8- Zone Assigned to Partition 8

Zone Definitions

0- Disabled (Default)

 8- 24Hr Gas

1- Entry Delay 1 

9- 24Hr Heat

2- Entry Delay 2 

A- 24Hr Water

3- Follow 

B- 24Hr Freeze

4- Instant

C- Delayed 24Hr Fire

5- 24Hr Buzzer

D- Standard 24Hr Fire

6- 24Hr Burglary

E- Stay Delay 1

7- 24Hr Hold-up

F- Stay Delay 2

Zone Numbering

Sections [0001] to [0096] represent 

zones 1 to 96 respectively

Zone Parameters

Sections [0101] to [0196] represent 

zones 1 to 96 respectively

Select one 

only

Select one 

or more

Select one 

only

Input

 2

Hardwired

Device B

Control Panel

SN#:020000A2

APR3-ZX8 Module

SN#: 34000041

Input 5

Detector A

SN#: 21000033

C

OMMUNICATION

 N

ETWORK

Input Terminals

1     2     3     4     5     6     7     8

Detector A:
Hardwired Device A:
Hardwired Device B:
Hardwired Device C:

Zone#

1 =
2 =
3 =
4 =

Section#

[0001]
[0002]
[0003]
[0004]

Serial#

21000033
1A000252
020000A2
34000041

Input#

N/A
N/A
002
005

Keypad

SN#: 1A000252

Keypad Zone

Hardwired

Device C

Hardwired

Device A

Input Terminals

1     2     3     4     5     6     7     8

Combus

Содержание DIGIPLEX DGP-NE96

Страница 1: ...V1 5 96 Zone Expandable Security and Access Control Panel DGP NE96 Reference and Installation Manual DGP NE96 www paradox ca...

Страница 2: ......

Страница 3: ...e 16 Restrict Arming on Module Troubles 16 Timed Auto Arming 16 No Movement Auto Arming 17 Auto Arming Options 17 Switch To Stay Arming 17 Always Force Arm when Regular Arming 17 Follow Zone Switches...

Страница 4: ...evels 36 Access Schedules 36 Backup Schedules 37 Holiday Programming 37 Schedule Tolerance Window 37 Door Access Mode 37 Code Access 37 Card and Code Access 37 Skip Exit Delay When Arming With Access...

Страница 5: ...the CTR 21 approval are available as an option only 1 1 Features Digital combus Provides constant power supervision and two way communication between the control panel and all its modules Supports up...

Страница 6: ...a 12Vdc 4Ah rechargeable acid lead or gel cell backup battery YUASA model NP7 12 recommended as shown in Figure 3 on page 3 Connect the backup battery after applying AC power When installing verify pr...

Страница 7: ...resistor as close as possible to the bell A resistor is not required for sirens The bell output will shut down if the current exceeds 3A Bell Siren 1K9 resistor Bell Siren 1K9 resistor Transformer Re...

Страница 8: ...ion Module DGP2 ZX1 _______ X 14PU __________ PU 4 Zone Hardwire Module APR3 ZX4 _______ X 28PU __________ PU 8 Zone Hardwire Module APR3 ZX8 _______ X 28PU __________ PU Wireless Module OMN RCV3 ____...

Страница 9: ...rdwired input terminals for use with traditional hardwired non combus door contacts smoke detectors and or motion detectors The control panel also supports several hardwire zone expansion modules Devi...

Страница 10: ...nsion Plug in Device DGP2 ZX4 provides four additional hardwired input terminals 8 zones with ATZ enabled It connects directly to the control panel through its on board EXPANSION connector as shown in...

Страница 11: ...ote Not to be used with UL Listed systems 2 17 2 ESL CleanMe Installation The DGP NE96 control panel supports ESL smoke detectors that have the CleanMe feature Connect ESL smoke detectors like the sta...

Страница 12: ...ored in the RTC every hour If the times are different the DGP NE96 will reset its internal clock to the time saved in the RTC The RTC uses a 3V lithium battery CR2032 with a battery life of 11 years C...

Страница 13: ...he next section Press the right action key Exit to revert to the preceding step or press the left action key Clear to erase the current data 3 4 1 Feature Select Programming Most of the options are pr...

Страница 14: ...d to it Enter the module s 3 digit INPUT NUMBER where the hardwire device is connected NOTE For addressable PIRs door contacts and keypads no input is required Zone Definition First Digit Zone Partiti...

Страница 15: ...ters through the entry point to disarm the system 4 3 4 Instant Zones SECTIONS 0101 TO 0196 FIRST DIGIT 4 When an armed Instant zone opens the control panel immediately generates an alarm Instant zone...

Страница 16: ...ction 4 3 4 on page 11 When a Stay Delay zone is armed using the Stay or Instant arming methods and the zone is triggered the control panel will not generate an alarm until the programmed Stay Delay e...

Страница 17: ...e into effect until the Input Speed elapses The control panel will not display and or respond to an open zone until the Input Speed elapses to prevent glitches from causing an alarm or unnecessary rep...

Страница 18: ...tion using the Maintained Keyswitch turn the switch from the ON to the OFF position To disarm a partition set the keyswitch in the ON position The selected Keyswitch Option see section 5 4 on page 15...

Страница 19: ...ing the security system into eight completely independent systems Therefore each keyswitch must be assigned to one partition as shown in Figure 17 on page 14 For details on Partitioning see section 11...

Страница 20: ...le if options 1 2 and 5 are ON in section 3035 the control panel prevents arming if it detects an AC or battery failure on the control panel or on a module connected to the combus 6 9 Timed Auto Armin...

Отзывы: