Zone Programming
Zone
Description
Module
Section
8-digit Serial Number
Input#
Section
Define
Assign
Zone Options
1
________________________
_______________
[0001]
___/___/___/___/___/___/___/___
___/___/___
[0101]
___
___
1 2 3 4 5 6 7 8
2
________________________
_______________
[0002]
___/___/___/___/___/___/___/___
___/___/___
[0102]
___
___
1 2 3 4 5 6 7 8
3
________________________
_______________
[0003]
___/___/___/___/___/___/___/___
___/___/___
[0103]
___
___
1 2 3 4 5 6 7 8
4
________________________
_______________
[0004]
___/___/___/___/___/___/___/___
___/___/___
[0104]
___
___
1 2 3 4 5 6 7 8
5
________________________
_______________
[0005]
___/___/___/___/___/___/___/___
___/___/___
[0105]
___
___
1 2 3 4 5 6 7 8
6
________________________
_______________
[0006]
___/___/___/___/___/___/___/___
___/___/___
[0106]
___
___
1 2 3 4 5 6 7 8
7
________________________
_______________
[0007]
___/___/___/___/___/___/___/___
___/___/___
[0107]
___
___
1 2 3 4 5 6 7 8
8
________________________
_______________
[0008]
___/___/___/___/___/___/___/___
___/___/___
[0108]
___
___
1 2 3 4 5 6 7 8
9
________________________
_______________
[0009]
___/___/___/___/___/___/___/___
___/___/___
[0109]
___
___
1 2 3 4 5 6 7 8
10
________________________
_______________
[0010]
___/___/___/___/___/___/___/___
___/___/___
[0110]
___
___
1 2 3 4 5 6 7 8
11
________________________
_______________
[0011]
___/___/___/___/___/___/___/___
___/___/___
[0111]
___
___
1 2 3 4 5 6 7 8
12
________________________
_______________
[0012]
___/___/___/___/___/___/___/___
___/___/___
[0112]
___
___
1 2 3 4 5 6 7 8
13
________________________
_______________
[0013]
___/___/___/___/___/___/___/___
___/___/___
[0113]
___
___
1 2 3 4 5 6 7 8
14
________________________
_______________
[0014]
___/___/___/___/___/___/___/___
___/___/___
[0114]
___
___
1 2 3 4 5 6 7 8
15
________________________
_______________
[0015]
___/___/___/___/___/___/___/___
___/___/___
[0115]
___
___
1 2 3 4 5 6 7 8
16
________________________
_______________
[0016]
___/___/___/___/___/___/___/___
___/___/___
[0116]
___
___
1 2 3 4 5 6 7 8
17
________________________
_______________
[0017]
___/___/___/___/___/___/___/___
___/___/___
[0117]
___
___
1 2 3 4 5 6 7 8
18
________________________
_______________
[0018]
___/___/___/___/___/___/___/___
___/___/___
[0118]
___
___
1 2 3 4 5 6 7 8
19
________________________
_______________
[0019]
___/___/___/___/___/___/___/___
___/___/___
[0119]
___
___
1 2 3 4 5 6 7 8
20
________________________
_______________
[0020]
___/___/___/___/___/___/___/___
___/___/___
[0120]
___
___
1 2 3 4 5 6 7 8
21
________________________
_______________
[0021]
___/___/___/___/___/___/___/___
___/___/___
[0121]
___
___
1 2 3 4 5 6 7 8
22
________________________
_______________
[0022]
___/___/___/___/___/___/___/___
___/___/___
[0122]
___
___
1 2 3 4 5 6 7 8
23
________________________
_______________
[0023]
___/___/___/___/___/___/___/___
___/___/___
[0123]
___
___
1 2 3 4 5 6 7 8
Input
2
Hardwired
Device B
Control Panel
SN#:020000A2
APR3-ZX8 Module
SN#: 34000041
Input 5
Detector A
SN#: 21000033
C
OMMUNICATION
N
ETWORK
Input Terminals
1 2 3 4 5 6 7 8
Detector A:
Hardwired Device A:
Hardwired Device B:
Hardwired Device C:
Zone#
1 =
2 =
3 =
4 =
Section#
[0001]
[0002]
[0003]
[0004]
Serial#
21000033
1A000252
020000A2
34000041
Input#
N/A
N/A
002
005
Keypad
SN#: 1A000252
Keypad Zone
Hardwired
Device C
Hardwired
Device A
Input Terminals
1 2 3 4 5 6 7 8
Combus
When option
[1]
in section
[3030]
is enabled for PGM1
to act as a zone input for two-wire smoke detectors,
the control panel will recognize PGM1 as input number
255.
Zone Definitions
0 - Disabled
(default)
8
- 24Hr Gas
1
- Entry Delay 1
9
- 24Hr Heat
2
- Entry Delay 2
A
- 24Hr Water
3
- Follow
B
- 24Hr Freeze
4
- Instant
C
- Delayed 24Hr Fire
5
- 24Hr Buzzer
D
- Standard 24Hr Fire
6
- 24Hr Burglary
E
- Stay Delay 1
7
- 24Hr Hold-up
F
- Stay Delay 2
Zone Options
[1]
Auto Zone Shutdown Enabled
[2] Bypass Enabled
(default)
[3]
Stay Zone
[4]
Force Zone
[5]
[6]
Zone Alarm Type
off
off
Steady Alarm
off
on
Pulsed Alarm
on
off
Silent Alarm
on
on
Report Only
[7]
Intellizone
[8]
Delay before Transmission
Zone Partition Assignment
1 - Assigned to Partition 1
(default)
5
- Assigned to Partition 5
2
- Assigned to Partition 2
6
- Assigned to Partition 6
3
- Assigned to Partition 3
7
- Assigned to Partition 7
4
- Assigned to Partition 4
8
- Assigned to Partition 8
Zone Numbering
Sections
[0001]
to
[0096]
represent zones
1 through 96. This feature allows you to
assign an addressable or hardwired
detection device to the desired zone.
Enter 3-digit
[
INPUT
NUMBER
]
of the
Module to which the hardwired detection
device is connected. NOTE: No input
number is required for Addressable
Detectors, door contacts, or Keypad
Zones.
Enter 8-digit
[
SERIAL
NUMBER
]
of the
Addressable Detector, door contact, or
Module to which the hardwired detection
device is connected.
Zone Parameters
Sections
[0101]
to
[0196]
represent zones 1 through 96. This feature defines the
type of zone, its partition assignment and the zone’s options.