Special and Trouble Report Codes
Ademco slow, Silent Knight fast, SESCOA, Ademco express or Pager formats:
Key-in desired 2-digit hex values from 00 to FF.
Ademco format:
Use sections
[4034]
(Special System Report Codes),
[4035]
(Special Arming/Disarming Report Codes),
[4036]
(Special Alarm Report Codes) and
[4037]
(Trouble/Trouble Restore Report Codes) to program a set of default Ademco report codes from the
Automatic Report Code Programming
on page 41. Then
to program the remaining report codes or to change some of the defaults, enter the individual sections and key-in the desired 2-digit hex value found in the
SIA format:
Use sections
[4034]
(Special System Report Codes),
[4035]
(Special Arming/Disarming Report Codes),
[4036]
(Special Alarm Report Codes) and
[4037]
(Trouble/Trouble Restore Report Codes) to program a set of SIA report codes from the
Automatic Report Code Programming
on page 41. Codes that have
not been set to default can be set to default manually by entering FF in the appropriate section. To disable the reporting of an event, enter 00 in the
appropriate section.
Special System Report Codes
Special Alarm Report Codes
Section
Report Code
Section
Report Code
[3900]
__/__ Power up after total power down
[3930]
__/__ Emergency Panic
[3901]
__/__ Software reset (Watchdog)
[3931]
__/__ Auxiliary Panic
[3902]
__/__ Test Report
[3932]
__/__ Fire Panic
[3903]
Future Use
[3933]
__/__ Recent Closing
[3904]
__/__ WinLoad Login Request
[3934]
__/__ Police Code
[3905]
__/__ WinLoad Log Off
[3935]
__/__ Zone Shutdown
[3906]
__/__ Installer In
[3936]
__/__ Duress
[3907]
__/__ Installer Out
[3937]
__/__ Keypad Lockout
[3908]
Future Use
[3938]
Future Use
[3909]
Future Use
[3939]
Future Use
Special Arming Report Codes
Trouble Report Codes
Section
Report Code
Section
Report Code
[3910]
__/__ Auto-arming
[3940]
__/__ TLM1 Failure
[3911]
__/__ PC Arming
[3941]
__/__ AC Failure
[3912]
__/__ Late to Close (Auto-arming)
[3942]
__/__ Battery Failure
[3913]
__/__ No Movement
[3943]
__/__ Auxiliary Supply
[3914]
__/__ Partial Arming
[3944]
__/__ Bell Output (Disconnected or overload)
[3915]
__/__ Quick Arming
[3945]
__/__ Clock Loss
[3916]
__/__ Early to Close
(refer to “Arming Report Schedules” on page 34)
[3946]
__/__ Fire Loop Trouble
[3917]
__/__ Late to Close
(refer to “Arming Report Schedules” on page 34)
[3947]
Future Use
[3918]
__/__ Remote Arming (APR3-ADM2)
[3948]
Future Use
[3919]
__/__ Closing Delinquency
[3949]
Future Use
[3950]
__/__ Combus Fault
Special Disarming Report Codes
[3951]
__/__ Module Tamper
Section
Report Code
[3952]
__/__ ROM Check Error
[3920]
__/__ Cancel Auto-arm
[3953]
__/__ Module TLM
[3921]
__/__ Quick Disarm
[3954]
__/__ Module Failure to Communicate
[3922]
__/__ PC Disarming
[3955]
__/__ Printer Fault
[3923]
__/__ PC Disarming after alarm
[3956]
__/__ Module AC Failure
[3924]
__/__ Cancel Alarm
[3957]
__/__ Module Battery Failure
[3925]
Future Use
[3958]
__/__ Module Auxiliary Failure
[3926]
__/__ Early to Open
(refer to “Disarming Report Schedules” on page 34)
[3959]
Future Use
[3927]
__/__ Late to Open
(refer to “Disarming Report Schedules” on page 34)
[3960]
__/__ Wireless Transmitter Battery Low
[3928]
__/__ Remote Disarming (APR3-ADM2)
[3961]
__/__ Wireless Transmitter Supervision Trouble
[3929]
Future Use
[3962]
Future Use
[3963]
Future Use
[3964]
Future Use
[3965]
__/__ Phone Number 1 Fail to Communicate