Digiplex DGP-NE96
- 31 -
Programming Guide
Other Options
Schedule Tolerance Window
Telephone Line Monitoring (TLM) Options
(Section
[3036]
; options
[1]
&
[2]
)
Auto-Test Report Transmission Options
(Section
[3037]
; options
[3]
&
[4]
)
[1]
[2]
[3]
[4]
OFF
OFF
ON
ON
OFF
ON
OFF
ON
Disabled
(default)
When armed:
GENERATES
AN
AUDIBLE
ALARM
When armed:
GENERATES
A
TROUBLE
TLM silent alarm:
BECOMES
AN
AUDIBLE
ALARM
OFF OFF
Transmit the test report code every time the days programmed
in section
[3040]
have elapsed at the time programmed in
section
[3041]
(default).
OFF ON
When disarmed:
Transmit test report code every time the
time programmed in section
[3043]
has elapsed.
When armed:
Transmit test report code every time the time
programmed in section
[3042]
has elapsed.
ON
OFF The control panel will transmit the test report code every hour
on the minute value programmed in section
[3041]
(the last
two digits). Note that the first two digits of section
[3041]
will
be ignored.
For example, if 10:25 was programmed into
section
[3041]
, the test report code would be transmitted at
the 25
th
minute of every hour, i.e. 11:25, 12:25, etc.
ON
ON
The test report code will be transmitted when any of the
conditions of the second and third options listed above
(options
[3]
= OFF and
[4]
= ON / options
[3]
= ON and
[4]
=
OFF) are met.
Section
Data
Description
Default
[3039]
__/__/__ ( x 1 minute)
S
CHEDULE
TOLERANCE
WINDOW
000
Auto Test Report Settings
Section
Data
Description
Default
[3040]
__/__/__ ( x 1 day; 000 = disabled)
A
UTO
TEST
REPORT
000
[3041]
__/__ : __/__ Hrs (00-23) & Mins (00-59)
A
UTO
TEST
REPORT
TIME
OF
DAY
00 : 00
[3042]
__/__/__ (000 - 255 x 1 minute)
A
RMED
REPORT
DELAY
5 minutes
[3043]
__/__/__ (000 - 255 x 1 minute)
D
ISARMED
REPORT
DELAY
60 minutes
= Default setting
SECTION [3038]: Access Control Options
Option
OFF
ON
[1]
Access control feature
Disabled
N
Enabled
[2]
Log “Request for Exit” in event
buffer*
Disabled
N
Enabled
[3]
Log “Door Left Open Restore” in
event buffer
Disabled
N
Enabled
[4]
Log “Door Forced Restore” in event
buffer
Disabled
N
Enabled
[5]
Burglar alarm on forced door
Disabled
N
Enabled
[6]
Skip exit delay when arming with
access card
Disabled
N
Enabled
[7]
Burglar alarm on door left open
Disabled
N
Enabled
[8]
Who has access during clock loss
All users
N
Masters
* Since “Request for Exit” events can occur often, the Event
Buffer may fill up quickly.