![background image](http://html2.mh-extra.com/html/paradox/digiplex-dgp-620/digiplex-dgp-620_installers-manual_3620540021.webp)
Digiplex LED Keypads 19
normal state (deactivate) when the event programmed in section
[008]
occurs unless the keypad is in
PGM Timed Mode
(see
section 5.4 of this manual). The PGM Deactivation Event is
programmed in the same manner as the
PGM Activation Event
.
5.4 PGM T
IMED
M
ODE
Section 005: Option [2]
If the keypad is in PGM Timed Mode, the keypad's on-board
PGM will be deactivated according to the
PGM Timer
(see
section 5.5 of this manual) instead of the
PGM Deactivation
Event
.
Option
[2]
OFF= Deactivation as per PGM Deactivation Event (default)
Option
[2]
ON = PGM will deactivate according to the PGM Timer
5.5 PGM T
IMER
Section 006
If the keypad's on-board PGM is in
PGM Timed Mode
, the value
programmed in section
[006]
represents how long the PGM will
remain in its opposite state (see section 5.1 of this manual) after
being activated. To program the timer, enter a 3-digit decimal
value (000 to 255) in section
[006]
. The 3-digit value will be
multiplied by the
PGM Base Time
of 1 second or 1 minute (see
section 5.6 of this manual).