Table 8-12: Detailed Thresholds
thresholdIndex/
thresholdValue
thresholdTextValue
Value OID
Description
1/INTEGER
LowCurrentThresholdPS2'0..1023 1.3.6.1.4.1.20712.2.1.2.1.2.1
Power Supply 2 Low DC Current alarm
threshold (Amps x10)
2/INTEGER
SpareFaultLowLimitThreshold'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.2
Spare Fault alarm low threshold
3/INTEGER
SpareFaultHighLimitThreshold'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.3
Spare Fault alarm high threshold
4/INTEGER
LowCurrentThresholdPS1'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.4
Power Supply 1 Low DC current alarm
threshold (Amps x10)
5/INTEGER
LowVoltageThresholdPS2'0..1023 1.3.6.1.4.1.20712.2.1.2.1.2.5
Power Supply 2 Low Regulator voltage
alarm threshold (Volts x10)
6/INTEGER
LowVoltageThresholdPS1'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.6
Power Supply 1 Low Regulator voltage
alarm threshold (Volts x10)
Table 8-13: Detailed Conditions
conditionIndex/
conditionValue
conditionTextValue
Value OID
Description
1/INTEGER
AttenDACCount'0..4095 1.3.6.1.4.1.20712.2.1.3.1.2.1
Attenuation DAC control output
2/INTEGER
SSPACoreTemperature(C)'-100..100
1.3.6.1.4.1.20712.2.1.3.1.2.2
SSPA core temperature
3/INTEGER
FaultStateAgregateValue'0-65535
1.3.6.1.4.1.20712.2.1.3.1.2.3
Aggregate Fault State of SSPA
4/INTEGER
SSPAAgregateAttenuation(dBx10)'0..200
1.3.6.1.4.1.20712.2.1.3.1.2.4
Current SSPA Attenuation Level
5/INTEGER
ForwardRFPower(dBmx10)'0..800
1.3.6.1.4.1.20712.2.1.3.1.2.5
Forward RF Forward output in dBm
6/INTEGER
SSPADCCurrent(Ampx10)'0..10000
1.3.6.1.4.1.20712.2.1.3.1.2.6
SSPA DC current consumption
7/INTEGER
PS2RegulatorVoltage(Voltx10)'0..600 1.3.6.1.4.1.20712.2.1.3.1.2.7
Power Supply 2 Regulator Output volt-
age
8/INTEGER
PS2Voltage(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.8
Power Supply 2 Voltage
9/INTEGER
GateVoltage(Voltx10)'0..200 1.3.6.1.4.1.20712.2.1.3.1.2.9
RF FET Bias Gate voltage
10/INTEGER
PS1DCCurrent(Ampx10)'0..10000
1.3.6.1.4.1.20712.2.1.3.1.2.10
Power Supply 1 Regulated DC current
consumption
11/INTEGER
PS1RegulatorVoltage(Voltx10)'0..600 1.3.6.1.4.1.20712.2.1.3.1.2.11
Power Supply 1 Regulator Output volt-
age
12/INTEGER
PS1Voltage(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.12
Power Supply 1 Output Voltage
13/INTEGER
ExternalReferenceLevel'0..1023 1.3.6.1.4.1.20712.2.1.3.1.2.13
External Reference Level (If BUC is
installed, if not present always 0)
14/INTEGER
BaseplateTemperature(C)'-100..100
1.3.6.1.4.1.20712.2.1.3.1.2.14
SSPA Base Plate temperature
15/INTEGER
TempcoDACCount'0..4095 1.3.6.1.4.1.20712.2.1.3.1.2.15
Tempcom DAC control output
Содержание RA 5785
Страница 8: ...8 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...12 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...46 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 56: ...56 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 82: ...82 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA...