Issue Diagnosis
Issue Diagnosis
Issue
Potential Solution
• Battery terminals hot.
• Check tightness of battery terminals,
ensure no corrosion or debris is built up on
terminals.
• Battery not staying charged.
• Ensure battery fluid level is topped up, plug
in trickle charge or solar charger, ensure
solar panel is getting sunlight.
• Remote control not working.
• Replace batteries, try using remote
at a closer location. Verify that the lift
operates with the hard wired controller.
Electromagnetic interference could disrupt
signal.
• Lift does not actuate with hard wired
controller.
• Check battery voltage. Verify that all wires
are plugged in. Check that the hydraulic
pump motor is actuating.
• Hydraulic hoses are difficult to connect.
• Check for debris on threads. Use a wrench to
connect quick disconnects. Depressurize the
system as described in Step 10 of Assembly
Instructions.
• Hydraulic fluid in power pack box.
• Fluids may have overflowed due to air in
system. Check all fittings and tighten as
necessary.
• Lift is noisy/squeaky when operating.
• Tighten all bolts and relubricate all pins with
marine grease.
• RC unit won’t work
• Check that RC unit fuse is good. Shown in
picture below: