Operations Manual, HPA2, Compact Outdoor SSPA
208495 REV B
69
7.2 Tests for units with integrated zBUC
If the Compact Outdoor amplifier includes a block up converter (zBUC), the following tests are
included.
7.2.1 Reference Lock
This test checks the external/internal references (if equipped), as well as lowest locking level
at 10 MHz. See
Figure 7-3, item
[
5
]
.
7.2.2 FSK
Verifies FSK communication with the zBUC. See
Figure 7-3, item
[
6
]
.
7.2.3 Phase Noise
Tests phase noise using external and internal (if equipped) references. The unit is required to
meet at each decade, as well as fall below the spec line determined by the decades. See
Figure 7-2, item
[
4
]
.
7.2.4 Microphonics
A spectrum analyzer is connected to the unit and is set to perform a max hold on the trace, .
The unit is then tested as per our procedure.
Содержание 205486 REV F
Страница 10: ...10 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...24 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...60 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...Operations Manual HPA2 Compact Outdoor SSPA 208495 REV B 91 Figure 9 22 Schematic 1 2 Redundant System ...
Страница 96: ...96 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 138: ...138 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...144 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...