Operations Manual, HPA2, Compact Outdoor SSPA
208495 REV B
105
You may alternately use the FPRC-1100 controller’s output power display (available by
pressing the
Main Menu
key; select
5.Options
and press the
Enter
key; select
6.More
and
press the
Enter
key; select
5.SSPA
and press the
Enter
key; select
3.View
and press the
Enter
key. The System Forward RF Output Power is shown in the upper right of the display).
Remove the cover from the Signal Box and loosen the
locking nut on the phase adjuster (7/16”) and slowly rotate
the knob clockwise. See
Figure 10-8
. Continue to rotate
the knob until the output power is peaked.
For optimum performance across the entire frequency
range of the SSPA system, choose another frequency
near each band edge and repeat the steps above. It may
be necessary to find the best compromise in output power
for broadband use.
The BUCs are outside the phase combined loop. Therefore, replacing a BUC will not impact
the phase combining of the system, and no adjustment of the phase shifter is necessary.
Once the phase adjustments are complete, tighten the locking nut on the phase adjustment
knob and securely fasten the cover back on to the Signal Box.
10.4 1:2 Fixed Phase Combined Systems
The 1:2 Fixed Phase Combined Redundant System is a popular system architecture that
enables Solid State Power Amplifiers to achieve higher output power levels while building in
full-power redundancy. The basic system topology is similar to a 1:2 redundant system and is
shown in
Figure 10-9
.
In this system, amplifiers #1 and #3 are normally online. The outputs of #1 and #3 are
directed by the waveguide switches into a fixed phase combiner such as a waveguide “magic
tee” style combiner. In the event of a failure of either on line amplifier, the standby amplifier,
#2, can be switched in place of either #1 or #3 and the system maintains full output power.
Figure 10-9: Block Diagram, 1:2 Fixed Phase Combined System
Figure 10-8: Phase adjuster
Содержание 205486 REV F
Страница 10: ...10 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...24 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...60 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...Operations Manual HPA2 Compact Outdoor SSPA 208495 REV B 91 Figure 9 22 Schematic 1 2 Redundant System ...
Страница 96: ...96 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 138: ...138 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...144 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...