3.3 Quick Start Connections
This section describes the necessary steps to communicate with a Compact Outdoor SSPA
using either the Ethernet or RS-232 Quick Start cables and the Universal M&C Software.
The Teleydne Paradise Datacom Universal M&C Software is a free Windows-based
application that can be downloaded from the company web site, www.paradisedata.com.
Download version 4.4.3 or later.
3.3.1 Set PC Configuration
To set your Windows-based PC to remotely communicate with the Compact Outdoor unit,
perform the following steps:
If using Windows XP:
1. Open the PC’s
Control Panel
(
Start Menu
→
Settings
→
Control Panel
);
2. Double-click on the
Network Connections
icon;
3. Right-click on the
Local Area Connection
icon and select
Properties
;
4. Select
Internet Protocol (TCP/IP)
and click on the
Properties
button;
5. Select “
Use the following IP address
” and enter the following information:
IP address
: 192.168.0.1
Subnet mask
: 255.255.255.0
6. Click the “
OK
” button and close out of the
Control Panel
windows.
If using Windows Vista or Windows 7:
1. Click on the Windows icon in the lower left corner and select
Control Panel
;
2. Click on the
Network and Sharing Center
link;
3. Click on the
Local Area Connection
link;
4. Click on the
Properties
button;
5. Select
Internet Protocol Version 4 (TCP/IP v4)
and click on the
Properties
button;
6. Select “
Use the following IP address
” and enter the following information:
IP address
: 192.168.0.1
Subnet mask
: 255.255.255.0
7. Click the “
OK
” button and close out of all of the
Control Panel
windows.
3.3.2 Quick Start Ethernet Connection
The following steps outline how to quickly connect to your Compact Outdoor SSPA using the
Ethernet Quick Start cable.
1. Unpack the amplifier and connect the RF Input and RF Output.
2.
Ensure the J1 RF Output port is properly terminated.
3. Connect the AC input power to connector J7.
4.
When shipped from the factory, the Compact Outdoor SSPA is set to start up
muted.
5. Connect the supplied “Quick-Start” Control Cable from Port J4 to the Ethernet port on
your computer. This connection will unmute the amplifier. Review the cable schematic
in
Figure 3-7
.
6. Launch the Windows-based Teledyne Paradise Datacom Universal M&C Software.
Содержание 205486 REV F
Страница 10: ...10 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...24 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...60 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...Operations Manual HPA2 Compact Outdoor SSPA 208495 REV B 91 Figure 9 22 Schematic 1 2 Redundant System ...
Страница 96: ...96 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 138: ...138 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...144 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...