Operations Manual, HPA2, Compact Outdoor SSPA
208495 REV B
135
Table 11-12: Detailed Thresholds
thresholdIndex/
thresholdValue
thresholdTextValue
Value OID
Description
1/INTEGER
LowCurrentThresholdMaster'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.1
Master side Low DC Current alarm
threshold (Amps x10)
2/INTEGER
SpareFaultLowLimitThreshold'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.2
Spare Fault alarm low threshold
3/INTEGER
SpareFaultHighLimitThreshold'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.3
Spare Fault alarm high threshold
4/INTEGER
LowCurrentThresholdSlave'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.4
Slave side Low DC current alarm
threshold (Amps x10)
5/INTEGER
LowVoltageThresholdMaster'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.5
Master side Low Regulator voltage
alarm threshold (Volts x10)
6/INTEGER
LowVoltageThresholdSlave'0..1023
1.3.6.1.4.1.20712.2.1.2.1.2.6
Slave side Low Regulator voltage alarm
threshold (Volts x10)
Table 11-13: Detailed Conditions
conditionIndex/
conditionValue
conditionTextValue
Value OID
Description
1/INTEGER
DACCount'0..1023
1.3.6.1.4.1.20712.2.1.3.1.2.1
Tempcomp DAC control output
2/INTEGER
SSPACoreTemperature(C)'-100..100
1.3.6.1.4.1.20712.2.1.3.1.2.2
SSPA core temperature
3/INTEGER
FaultStateAgregateValue'0-65535
1.3.6.1.4.1.20712.2.1.3.1.2.3
Aggregate Fault State of SSPA
4/INTEGER
SSPAAgregateAttenuation(dBx10)'0..200
1.3.6.1.4.1.20712.2.1.3.1.2.4
Current SSPA Attenuation Level
5/INTEGER
ForwardRFPower(dBmx10)'0..800
1.3.6.1.4.1.20712.2.1.3.1.2.5
Forward RF Forward output in dBm
6/INTEGER
SSPADCCurrent(Ampx10)'0..10000
1.3.6.1.4.1.20712.2.1.3.1.2.6
SSPA DC current consumption
7/INTEGER
RegulatorVoltage(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.7
DC Regulator Output Voltage
8/INTEGER
PSVoltage(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.8
Main Power Supply Voltage
9/INTEGER
GASFETGateVoltage(Voltx10)'0..200
1.3.6.1.4.1.20712.2.1.3.1.2.9
RF FET Bias Gate voltage
10/INTEGER
SSPADCCurrentSlave(Ampx10)'0..10000
1.3.6.1.4.1.20712.2.1.3.1.2.10
SSPA DC current consumption
(Slave side only, if not present
always 0)
11/INTEGER
RegulatorVoltageSlave(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.11
DC Regulator Output Voltage
(Slave side only, if not present
always 0)
12/INTEGER
PSVoltageSlave(Voltx10)'0..600
1.3.6.1.4.1.20712.2.1.3.1.2.12
Slave side Power Supply Voltage
(if not present always 0)
13/INTEGER
GASFETGateVoltageSlave(Voltx10)'0..200
1.3.6.1.4.1.20712.2.1.3.1.2.13
RF FET Bias Gate voltage (Slave
side, if not present always 0)
14/INTEGER
GASFETGateVoltagePreAmp(Voltx10)'0..200
1.3.6.1.4.1.20712.2.1.3.1.2.14
RF FET Bias Pre-Amp Gate voltage
(Slave side, if not present always 0)
Содержание 205486 REV F
Страница 10: ...10 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...24 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...60 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...Operations Manual HPA2 Compact Outdoor SSPA 208495 REV B 91 Figure 9 22 Schematic 1 2 Redundant System ...
Страница 96: ...96 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 138: ...138 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 144: ...144 208495 REV B Operations Manual HPA2 Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...