Panta Rhei hydro wizard ECM75 Скачать руководство пользователя страница 15

 

15 

 

Controller Instructions 

(Firmware 3.0.x)

 

Controlling the hydro wizard© 

 

 

The controller can be programmed  with your finger, or a non abrasive 
touch  screen  pen.  All  touch  surfaces  can  be  easily  reached  with  your 
finger.  When  activating  a  field  it  will  be  displayed  with  a  black 
background. When the finger is removed it will be confirmed.  

 
 
 
 
 

Figure 1: Touch screen surface confirmation 

 
The following will explain the most important fields of the touch screen.  
 

Warning: for maintenance

  ALWAYS

 disconnect the hydro  wizard 

from the power grid. Do not use any of the following stop functions 
to perform maintenance on the hydro wizard! 

 

The Information Screen 

The information screen displays information about the flow status of the 
pump. The upper part of the screen displays the flow mode. The center 
part  of  the  screen  will  display  the  most  important  data  about  the  flow 
mode.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2: Information screen 

 

 

Display active 

mode / stop 

Display: flow 

setting and 

performance 

time 

Stop hydro wizard

®

 

go to Main Menu 

Содержание hydro wizard ECM75

Страница 1: ...hydro wizard ECM75 User Manual...

Страница 2: ...mbH Gesch ftsf hrer Matthias K hlig Pappelweg 4 30179 Hannover Telefon 49 0 5130 60 957 27 Fax 49 0 5130 60 957 26 MAIL info panta rhei aquatics de WEB http www panta rhei aquatics de Version 430221b...

Страница 3: ...d 15 The Information Screen 15 The Menu Screen 17 The make changes screen 18 Menu structure 19 Operation 21 Flow mode 21 Wave mode 22 Connecting to the Panta Rhei BUS 24 Cleaning function 29 The Pause...

Страница 4: ...4 For your safety please read this document before using this product for the first time Keep these operation instructions so you can have access to this information at all times...

Страница 5: ...n with limited physical sensory or mental capacities or insufficient experience and or insufficient knowledge Unless they are supervised by a person responsible for their safety and are instructed how...

Страница 6: ...ariants with magnet mount The magnets included in this box are many times more powerful that conventional household magnets Do not bring these magnets close to devices that are sensitive to magnetic f...

Страница 7: ...ater is a basic function This eliminates dead zones in the water With the controller it is possible to generate wave simulations in which both wave height and length can be adjusted The pump can simul...

Страница 8: ...ral Description hydro wizard 1 Base 2 Motor 3 Nozzle Basket 4 Impeller 5 Stator Powerbox 1 Touchpad Display 2 Power connector 3 Connector for the Panta Rhei BUS 4 Connector hydro wizard 5 Attachment p...

Страница 9: ...9 Function The movement of the impeller generates an area of low pressure which pulls the water from the back through the basket and pushes it out the front over the fins of the stator...

Страница 10: ...block the impeller Are there any people inside the aquarium Positioning the pump Pay attention to the safety instructions on page 5 and 6 Do not use single bars as grip Always hold the motor with both...

Страница 11: ...submerged in water It must be installed deep enough to ensure it will not draw air from the surface Remember that in Wave mode the water level will change The pump can be installed directly above the...

Страница 12: ...will allow rising warm air to better carry heat away from the device Connect the plug of the motor right and the power cable left to the power supply Begin with a very low flow and carefully watch th...

Страница 13: ...e rotated through 360 To rotate the pump into any position loosen the hex screw inside the foot with a 10mm Allan key After the foot has been rotated to the desired position gently tighten the hex scr...

Страница 14: ...st not touch the casing Try to keep an equal distance between the tip of the impeller and the wall of the casing Turn the impeller by hand to check the distance in all points Do not overtighten the bo...

Страница 15: ...explain the most important fields of the touch screen Warning for maintenance ALWAYS disconnect the hydro wizard from the power grid Do not use any of the following stop functions to perform maintena...

Страница 16: ...l restart the hydro wizard When shipped the hydro wizard will arrive in Stop mode after it has been plugged in The MENU field will call up the main Menu The center of the screen will allow you to quic...

Страница 17: ...arrow at the right enters that submenu the arrow button on the left returns to the menu above To confirm this selection this item will get bigger to make them more visible Figure 5 confirmed return bu...

Страница 18: ...below are buttons to increase or decrease the number by the smallest step possible On the right side is a field that can be used like wheel it is used to increase or decrease the value smoothly with...

Страница 19: ...e 8 settings in flow mode Flow Settings Mode Info Quick access Duration Start Manuel Automatic Language Date Time Turn Tool Tip Active Password Main menu Settings Pause Cleaning Unit Password Depens o...

Страница 20: ...s in wave mode enter time Figure 10 settings in profil mode Current A Settings Current B Time A Time B Time B A Find frequency Time A B Phase delay New interval Settings Interval 1 Interval 3 Interval...

Страница 21: ...make a steady flow in the tank After selecting the flow mode select the strength of the flow in in the settings menu or the quick change field in the info menu If the pump is stopped blinking STOP fi...

Страница 22: ...ween two or three different flows These flows can be varied from 1 to 100 with the parameters flow A and flow B The Parameters time A and time B are used to select the duration of each action The para...

Страница 23: ...r stop the wave or flow mode automatically This allows waves or flow to be controlled individually for different time intervals To best understand the function of the wave and flow modes please read t...

Страница 24: ...Remove the protective caps fro the CAN sockets 2 Connect one power supply to the next as shown in the figure below Each socket can be used for in or out so the order in which they are connected is not...

Страница 25: ...ve it will take the settings of the Master automatically The information screen will display Slave and the settings transmitted by the Master If the connection is interrupted the unit will continue to...

Страница 26: ...wizard In this example the parallel usage of two hydro wizard are used to generate a stronger current or wave The Slave setting is used to achieve this pattern Requiered settings hydro wizard A Connec...

Страница 27: ...Settings hydro wizard A Connection Master Mode Welle Settings Current A 100 Settings Current B 1 Settings Time A 2s Settings Time B 2s hydro wizard B Vernetzung Sync Modus Wave Settings Current A 100...

Страница 28: ...while hydro wizard B will run from noon until midnight To achieve this the time must be synchronized in the SYNC mode Required Settings hydro wizard A Connection Master Mode Profile Settings New inte...

Страница 29: ...The Pause Feed timer The pause feed timer stops the hydro wizard and automatically resumes the programmed settings after an elapsed time i e during feeding The feed timer function can be reached from...

Страница 30: ...on is used to turn the orientation of the display by 180 degrees The menu selection reset returns all settings to the factory default The menu item restart is used to determine the action after power...

Страница 31: ...ubmerge the pump in the solution Leave the pump running for one hour Now discard the solution and run the pump for one more hour in clean fresh water This protocol should be performed once a year as a...

Страница 32: ...s in a change settings mode read the manual for the controller the pump is no longer generating a flow the intake basket is clogged clean the intake basket display Impeller failure hydro wizard don t...

Страница 33: ...30163 ohne Foto Power cord GER 429915 Patch cord Panta Rhei Bus 1m 11052277 terminating resistor Panta Rhei Bus 11052278 Titanium srew M12x35 423431 Titanium srew set M5x20 4 St ck 429430 Titanium sre...

Страница 34: ...34 Installation examples Figure shows accessories 428941 429430 428943 222651 223020 428782 428944 428960...

Страница 35: ...240 V 50 60Hz Max energy consumption 658 Watt Min speed 500 R min Max speed 1 800 R min Max output 160 000 L h Max liquid velocity 3 3 m s Axial force 120 N Max depth 10 m limited by cable Weight moto...

Страница 36: ...36 Dimensions All dimensions in mm Mount dimensions...

Страница 37: ...37 Dimensions Powerbox...

Страница 38: ...rvices Advice on flow design performance and positioning Advice on aquaculture show aquariums ponds and zoo applications Bespoke programming for special applications Integration in third party control...

Страница 39: ...nt Warranty exclusions The following are not covered by this warranty use for other than the intended purpose accidents or changes to the hardware or software unauthorized modifications an unsuitable...

Страница 40: ...Enjoy your new hydro wizard...

Отзывы: